{"answers":{"affected":"It affects 7 products.","exploited":"There is no known exploitation of CVE-2019-13933 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-13933 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-13933 is a high-severity missing authorization vulnerability in Siemens SCALANCE X204RNA (HSR), published on 16 Jan 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-13933 and fix it if it is affected.\n\nWhat it is: CVE-2019-13933 is a high-severity missing authorization vulnerability in Siemens SCALANCE X204RNA (HSR), published on 16 Jan 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-13933 in the wild and no public exploit code.\n\nAffected product: Siemens SCALANCE X204RNA (HSR). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-13933/ (Markdown: https://insights.sbomify.com/CVE-2019-13933/index.md)","id":"CVE-2019-13933","markdown":"https://insights.sbomify.com/CVE-2019-13933/index.md","name":"CVE-2019-13933","record":{"aliases":["GHSA-5vx5-pc42-77fx"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SCALANCE switch","requires_auth":"none","summary":"An attacker can bypass authentication mechanisms on Siemens SCALANCE industrial switches to access restricted functions.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"scalance_x-200rna_firmware","vendor":"siemens"},{"product":"scalance_x-300_firmware","vendor":"siemens"},{"product":"scalance_x204rna_firmware","vendor":"siemens"},{"product":"scalance_x408-2_firmware","vendor":"siemens"},{"product":"scalance_xr-300_firmware","vendor":"siemens"},{"product":"scalance_xr-300wg_firmware","vendor":"siemens"},{"product":"siplus_net_csm_1277_firmware","vendor":"siemens"}],"cvss":{"score":8.6,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SCALANCE X204RNA (HSR)","id":"CVE-2019-13933","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in Polarion","id":"CVE-2019-13934"},"packages":[],"prev":{"headline":"Other in XHQ","id":"CVE-2019-13932"},"products":["SCALANCE X204RNA (HSR)","SCALANCE X204RNA (PRP)","SCALANCE X204RNA EEC (HSR)","SCALANCE X204RNA EEC (PRP)","SCALANCE X204RNA EEC (PRP/HSR)","SCALANCE X302-7 EEC (230V)","SCALANCE X302-7 EEC (230V, coated)","SCALANCE X302-7 EEC (24V)","SCALANCE X302-7 EEC (24V, coated)","SCALANCE X302-7 EEC (2x 230V)","SCALANCE X302-7 EEC (2x 230V, coated)","SCALANCE X302-7 EEC (2x 24V)","SCALANCE X302-7 EEC (2x 24V, coated)","SCALANCE X304-2FE","SCALANCE X306-1LD FE","SCALANCE X307-2 EEC (230V)","SCALANCE X307-2 EEC (230V, coated)","SCALANCE X307-2 EEC (24V)","SCALANCE X307-2 EEC (24V, coated)","SCALANCE X307-2 EEC (2x 230V)","SCALANCE X307-2 EEC (2x 230V, coated)","SCALANCE X307-2 EEC (2x 24V)","SCALANCE X307-2 EEC (2x 24V, coated)","SCALANCE X307-3","SCALANCE X307-3LD","SCALANCE X308-2","SCALANCE X308-2LD","SCALANCE X308-2LH","SCALANCE X308-2LH+","SCALANCE X308-2M","SCALANCE X308-2M PoE","SCALANCE X308-2M TS","SCALANCE X310","SCALANCE X310FE","SCALANCE X320-1 FE","SCALANCE X320-1-2LD FE","SCALANCE X408-2","SCALANCE XR324-12M (230V, ports on front)","SCALANCE XR324-12M (230V, ports on rear)","SCALANCE XR324-12M (24V, ports on front)","SCALANCE XR324-12M (24V, ports on rear)","SCALANCE XR324-12M TS (24V)","SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","SCALANCE XR324-4M EEC (24V, ports on front)","SCALANCE XR324-4M EEC (24V, ports on rear)","SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","SCALANCE XR324-4M EEC (2x 24V, ports on front)","SCALANCE XR324-4M EEC (2x 24V, ports on rear)","SCALANCE XR324-4M PoE (230V, ports on front)","SCALANCE XR324-4M PoE (230V, ports on rear)","SCALANCE XR324-4M PoE (24V, ports on front)","SCALANCE XR324-4M PoE (24V, ports on rear)","SCALANCE XR324-4M PoE TS (24V, ports on front)","SIPLUS NET SCALANCE X308-2"],"published":"2020-01-16","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Siemens"]},"summary":"An attacker can bypass authentication mechanisms on Siemens SCALANCE industrial switches to access restricted functions.","url":"https://insights.sbomify.com/CVE-2019-13933/"}