{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2019-13947 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-13947 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-13947 is a medium-severity vulnerability in Siemens Control Center Server (CCS), published on 12 Dec 2019. An attacker needs administrator access to exploit it, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-13947 and fix it if it is affected.\n\nWhat it is: CVE-2019-13947 is a medium-severity vulnerability in Siemens Control Center Server (CCS), published on 12 Dec 2019. An attacker needs administrator access to exploit it, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-13947 in the wild and no public exploit code.\n\nAffected product: Siemens Control Center Server (CCS). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-13947/ (Markdown: https://insights.sbomify.com/CVE-2019-13947/index.md)","id":"CVE-2019-13947","markdown":"https://insights.sbomify.com/CVE-2019-13947/index.md","name":"CVE-2019-13947","record":{"aliases":["GHSA-x8ph-wcj9-ghxw"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens Control Center Server","requires_auth":"high_privilege","summary":"An attacker with admin privileges can read other users' passwords because the web interface transmits them in clear text.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sinvr_3_central_control_server","vendor":"siemens"},{"product":"sinvr_3_video_server","vendor":"siemens"}],"cvss":{"score":4.9,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N/E:F/RL:U/RC:C","version":"3.1"},"cwes":[{"id":"CWE-312","name":"Cleartext Storage of Sensitive Information"},{"id":"CWE-317","name":"Cleartext Storage of Sensitive Information in GUI"}],"description":"A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The user configuration menu in the web interface of the\nControl Center Server (CCS) transfers user passwords in clear to the\nclient (browser).\n\nAn attacker with administrative privileges for the web interface could be\nable to read (and not only reset) passwords of other CCS users.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in Control Center Server (CCS)","id":"CVE-2019-13947","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Cross-site scripting in n/a","id":"CVE-2019-13948"},"packages":[],"prev":{"headline":"Denial of service in Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller","id":"CVE-2019-13946"},"products":["Control Center Server (CCS)"],"published":"2019-12-12","related":[{"cvss_score":9.8,"headline":"Auth bypass in Control Center Server (CCS)","id":"CVE-2019-18337","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Auth bypass in SiNVR/SiVMS Video Server","id":"CVE-2019-18339","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":8.8,"headline":"SQL injection in Control Center Server (CCS)","id":"CVE-2019-19292","kev_date_added":null,"published":"2020-03-10"},{"cvss_score":7.7,"headline":"Path traversal in Control Center Server (CCS)","id":"CVE-2019-18338","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":7.5,"headline":"Path traversal in SiNVR/SiVMS Video Server","id":"CVE-2019-19297","kev_date_added":null,"published":"2020-03-10"},{"cvss_score":6.8,"headline":"Path traversal in SiNVR/SiVMS Video Server","id":"CVE-2019-19296","kev_date_added":null,"published":"2020-03-10"},{"cvss_score":6.5,"headline":"Path traversal in Control Center Server (CCS)","id":"CVE-2019-19290","kev_date_added":null,"published":"2020-03-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Siemens"]},"summary":"An attacker with admin privileges can read other users' passwords because the web interface transmits them in clear text.","url":"https://insights.sbomify.com/CVE-2019-13947/"}