{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2019-16966 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-16966 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-16966 is a medium-severity cross-site scripting vulnerability in Sangoma Freepbx, published on 21 Oct 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2019-16966 and fix it if it is affected.\n\nWhat it is: CVE-2019-16966 is a medium-severity cross-site scripting vulnerability in Sangoma Freepbx, published on 21 Oct 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2019-16966 in the wild and no public exploit code.\n\nAffected product: Sangoma Freepbx. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-16966/ (Markdown: https://insights.sbomify.com/CVE-2019-16966/index.md)","id":"CVE-2019-16966","markdown":"https://insights.sbomify.com/CVE-2019-16966/index.md","name":"CVE-2019-16966","record":{"aliases":["GHSA-vhvj-v5vw-v7x3"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["code_execution","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"FreePBX Contactmanager","requires_auth":"none","summary":"Reflected XSS in FreePBX Contactmanager allows attackers to execute arbitrary scripts in the admin interface via a crafted URL.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"contactmanager","vendor":"freepbx"},{"product":"freepbx","vendor":"sangoma"}],"cvss":{"score":6.1,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"An issue was discovered in Contactmanager 13.x before 13.0.45.3, 14.x before 14.0.5.12, and 15.x before 15.0.8.21 for FreePBX 14.0.10.3. In the Contactmanager class (html\\admin\\modules\\contactmanager\\Contactmanager.class.php), an unsanitized group variable coming from the URL is reflected in HTML on 2 occasions, leading to XSS. It can be requested via a GET request to /admin/ajax.php?module=contactmanager.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":false,"headline":"Cross-site scripting in n/a","id":"CVE-2019-16966","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"sangoma:freepbx","products":["sangoma:freepbx"],"type":"xss","year":"2019"},"n_packages":0,"n_references":3,"next":{"headline":"Cross-site scripting in n/a","id":"CVE-2019-16967"},"packages":[],"prev":{"headline":"Command injection in n/a","id":"CVE-2019-16965"},"products":["n/a"],"published":"2019-10-21","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Reflected XSS in FreePBX Contactmanager allows attackers to execute arbitrary scripts in the admin interface via a crafted URL.","url":"https://insights.sbomify.com/CVE-2019-16966/"}