{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2019-18241 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-18241 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-18241 is a medium-severity vulnerability in Philips IntelliBridge EC40 and EC80, published on 25 Nov 2019. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-18241 and fix it if it is affected.\n\nWhat it is: CVE-2019-18241 is a medium-severity vulnerability in Philips IntelliBridge EC40 and EC80, published on 25 Nov 2019. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-18241 in the wild and no public exploit code.\n\nAffected product: Philips IntelliBridge EC40 and EC80. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-18241/ (Markdown: https://insights.sbomify.com/CVE-2019-18241/index.md)","id":"CVE-2019-18241","markdown":"https://insights.sbomify.com/CVE-2019-18241/index.md","name":"CVE-2019-18241","record":{"aliases":["GHSA-p548-j649-rwfp"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["account_takeover","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Philips IntelliBridge Hub","requires_auth":"none","summary":"Weak SSH ciphers in Philips IntelliBridge hubs allow attackers to capture and replay sessions, potentially gaining unauthorized access.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"intellibridge_ec40_firmware","vendor":"philips"},{"product":"intellibridge_ec80_firmware","vendor":"philips"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-326","name":"Inadequate Encryption Strength"}],"description":"In Philips IntelliBridge EC40 and EC80, IntelliBridge EC40 Hub all versions, and IntelliBridge EC80 Hub all versions, the SSH server running on the affected products is configured to allow weak ciphers. This could enable an unauthorized attacker with access to the network to capture and replay the session and gain unauthorized access to the EC40/80 hub.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Weak cryptography in Philips IntelliBridge EC40 and EC80","id":"CVE-2019-18241","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower","id":"CVE-2019-18242"},"packages":[],"prev":{"headline":"Memory corruption in Fuji Electric V-Server 4.0.6 and prior","id":"CVE-2019-18240"},"products":["Philips IntelliBridge EC40 and EC80"],"published":"2019-11-25","related":[{"cvss_score":8.1,"headline":"Philips IntelliBridge EC 40 and EC 80 Hub Use of Hard-coded Credentials","id":"CVE-2021-32993","kev_date_added":null,"published":"2021-12-27"},{"cvss_score":8.1,"headline":"Philips IntelliBridge EC 40 and EC 80 Hub Authentication Bypass Using an Alternate Path or Channel","id":"CVE-2021-33017","kev_date_added":null,"published":"2021-12-27"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"Weak SSH ciphers in Philips IntelliBridge hubs allow attackers to capture and replay sessions, potentially gaining unauthorized access.","url":"https://insights.sbomify.com/CVE-2019-18241/"}