{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-18243 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-18243 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-18243 is a medium-severity vulnerability in HMI/SCADA iFIX, published on 18 Feb 2021. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-18243 and fix it if it is affected.\n\nWhat it is: CVE-2019-18243 is a medium-severity vulnerability in HMI/SCADA iFIX, published on 18 Feb 2021. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-18243 in the wild and no public exploit code.\n\nAffected product: HMI/SCADA iFIX. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-18243/ (Markdown: https://insights.sbomify.com/CVE-2019-18243/index.md)","id":"CVE-2019-18243","markdown":"https://insights.sbomify.com/CVE-2019-18243/index.md","name":"CVE-2019-18243","record":{"aliases":["GHSA-ggg4-fm7c-r5mq"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"HMI/SCADA iFIX","requires_auth":"low_privilege","summary":"A local authenticated user can escalate privileges by modifying system-wide iFIX configurations via the registry.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"ifix","vendor":"ge"}],"cvss":{"score":5.5,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"}],"description":"HMI/SCADA iFIX (Versions 6.1 and prior) allows a local authenticated user to modify system-wide iFIX configurations through the registry. This may allow privilege escalation.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in HMI/SCADA iFIX","id":"CVE-2019-18243","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in OSIsoft PI System multiple products and versions","id":"CVE-2019-18244"},"packages":[],"prev":{"headline":"Denial of service in Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower","id":"CVE-2019-18242"},"products":["HMI/SCADA iFIX"],"published":"2021-02-18","related":[{"cvss_score":7.8,"headline":"GE Digital Proficy Code Injection","id":"CVE-2023-0598","kev_date_added":null,"published":"2023-03-16"},{"cvss_score":5.5,"headline":"Privilege escalation in HMI/SCADA iFIX","id":"CVE-2019-18255","kev_date_added":null,"published":"2021-02-18"},{"cvss_score":4.8,"headline":"Other in iFix","id":"CVE-2018-17925","kev_date_added":null,"published":"2018-10-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["n/a"]},"summary":"A local authenticated user can escalate privileges by modifying system-wide iFIX configurations via the registry.","url":"https://insights.sbomify.com/CVE-2019-18243/"}