{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-18285 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-18285 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-18285 is a medium-severity vulnerability in Siemens SPPA-T3000 Application Server, published on 12 Dec 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-18285 and fix it if it is affected.\n\nWhat it is: CVE-2019-18285 is a medium-severity vulnerability in Siemens SPPA-T3000 Application Server, published on 12 Dec 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-18285 in the wild and no public exploit code.\n\nAffected product: Siemens SPPA-T3000 Application Server. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-18285/ (Markdown: https://insights.sbomify.com/CVE-2019-18285/index.md)","id":"CVE-2019-18285","markdown":"https://insights.sbomify.com/CVE-2019-18285/index.md","name":"CVE-2019-18285","record":{"aliases":["GHSA-mwpm-ch75-7qqj"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SPPA-T3000","requires_auth":"none","summary":"An attacker with network access can intercept unencrypted RMI traffic to read valid user credentials from the SPPA-T3000 Application Server.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sppa-t3000_application_server","vendor":"siemens"}],"cvss":{"score":5.9,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"A vulnerability has been identified in SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). The RMI communication between the client and the Application Server is unencrypted. An attacker with access to the communication channel can read credentials of a valid user. Please note that an attacker needs to have access to the Application Highway in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in SPPA-T3000 Application Server","id":"CVE-2019-18285","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Information disclosure in SPPA-T3000 Application Server","id":"CVE-2019-18286"},"packages":[],"prev":{"headline":"Missing authorization in SPPA-T3000 Application Server","id":"CVE-2019-18284"},"products":["SPPA-T3000 Application Server"],"published":"2019-12-12","related":[{"cvss_score":9.8,"headline":"Deserialization in SPPA-T3000 Application Server","id":"CVE-2019-18283","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Missing authorization in SPPA-T3000 Application Server","id":"CVE-2019-18284","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Deserialization in SPPA-T3000 Application Server","id":"CVE-2019-18314","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Auth bypass in SPPA-T3000 Application Server","id":"CVE-2019-18315","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Deserialization in SPPA-T3000 Application Server","id":"CVE-2019-18316","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":8.8,"headline":"File upload in SPPA-T3000 Application Server","id":"CVE-2019-18288","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":7.5,"headline":"Denial of service in SPPA-T3000 Application Server","id":"CVE-2019-18317","kev_date_added":null,"published":"2019-12-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Siemens"]},"summary":"An attacker with network access can intercept unencrypted RMI traffic to read valid user credentials from the SPPA-T3000 Application Server.","url":"https://insights.sbomify.com/CVE-2019-18285/"}