{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-18297 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-18297 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-18297 is a high-severity memory corruption vulnerability in Siemens SPPA-T3000 MS3000 Migration Server, published on 12 Dec 2019. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-18297 and fix it if it is affected.\n\nWhat it is: CVE-2019-18297 is a high-severity memory corruption vulnerability in Siemens SPPA-T3000 MS3000 Migration Server, published on 12 Dec 2019. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-18297 in the wild and no public exploit code.\n\nAffected product: Siemens SPPA-T3000 MS3000 Migration Server. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-18297/ (Markdown: https://insights.sbomify.com/CVE-2019-18297/index.md)","id":"CVE-2019-18297","markdown":"https://insights.sbomify.com/CVE-2019-18297/index.md","name":"CVE-2019-18297","record":{"aliases":["GHSA-vwhh-875j-gcqq"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens SPPA-T3000","requires_auth":"low_privilege","summary":"Local attackers with low privileges can gain root access via crafted packets to a named pipe in Siemens SPPA-T3000 MS3000.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sppa-t3000_ms3000_migration_server","vendor":"siemens"}],"cvss":{"score":7.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"},{"id":"CWE-122","name":"Heap-based Buffer Overflow"}],"description":"A vulnerability has been identified in SPPA-T3000 MS3000 Migration Server (All versions). An attacker with local access to the MS3000 Server and low privileges could gain root privileges by sending specifically crafted packets to a named pipe. Please note that an attacker needs to have local access to the MS3000 in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in SPPA-T3000 MS3000 Migration Server","id":"CVE-2019-18297","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Denial of service in SPPA-T3000 MS3000 Migration Server","id":"CVE-2019-18298"},"packages":[],"prev":{"headline":"Memory corruption in SPPA-T3000 MS3000 Migration Server","id":"CVE-2019-18296"},"products":["SPPA-T3000 MS3000 Migration Server"],"published":"2019-12-12","related":[{"cvss_score":9.8,"headline":"Memory corruption in SPPA-T3000 MS3000 Migration Server","id":"CVE-2019-18289","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Memory corruption in SPPA-T3000 MS3000 Migration Server","id":"CVE-2019-18293","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Memory corruption in SPPA-T3000 MS3000 Migration Server","id":"CVE-2019-18295","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Memory corruption in SPPA-T3000 MS3000 Migration Server","id":"CVE-2019-18296","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"File upload in SPPA-T3000 MS3000 Migration Server","id":"CVE-2019-18313","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Memory corruption in SPPA-T3000 MS3000 Migration Server","id":"CVE-2019-18323","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Memory corruption in SPPA-T3000 MS3000 Migration Server","id":"CVE-2019-18324","kev_date_added":null,"published":"2019-12-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Siemens"]},"summary":"Local attackers with low privileges can gain root access via crafted packets to a named pipe in Siemens SPPA-T3000 MS3000.","url":"https://insights.sbomify.com/CVE-2019-18297/"}