{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-18332 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-18332 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-18332 is a medium-severity vulnerability in Siemens SPPA-T3000 Application Server, published on 12 Dec 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-18332 and fix it if it is affected.\n\nWhat it is: CVE-2019-18332 is a medium-severity vulnerability in Siemens SPPA-T3000 Application Server, published on 12 Dec 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-18332 in the wild and no public exploit code.\n\nAffected product: Siemens SPPA-T3000 Application Server. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-18332/ (Markdown: https://insights.sbomify.com/CVE-2019-18332/index.md)","id":"CVE-2019-18332","markdown":"https://insights.sbomify.com/CVE-2019-18332/index.md","name":"CVE-2019-18332","record":{"aliases":["GHSA-p537-724w-94j9"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SPPA-T3000","requires_auth":"none","summary":"An attacker with network access can view directory listings on the SPPA-T3000 Application Server by sending crafted packets to specific ports.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sppa-t3000_application_server","vendor":"siemens"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"},{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"A vulnerability has been identified in SPPA-T3000 Application Server (All versions \u003c Service Pack R8.2 SP2). An attacker with network access to the Application Server could gain access to directory listings of the server by sending specifically crafted packets to 80/tcp, 8095/tcp or 8080/tcp. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in SPPA-T3000 Application Server","id":"CVE-2019-18332","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in SPPA-T3000 Application Server","id":"CVE-2019-18333"},"packages":[],"prev":{"headline":"Information disclosure in SPPA-T3000 Application Server","id":"CVE-2019-18331"},"products":["SPPA-T3000 Application Server"],"published":"2019-12-12","related":[{"cvss_score":9.8,"headline":"Deserialization in SPPA-T3000 Application Server","id":"CVE-2019-18283","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Missing authorization in SPPA-T3000 Application Server","id":"CVE-2019-18284","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Deserialization in SPPA-T3000 Application Server","id":"CVE-2019-18314","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Auth bypass in SPPA-T3000 Application Server","id":"CVE-2019-18315","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Deserialization in SPPA-T3000 Application Server","id":"CVE-2019-18316","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":8.8,"headline":"File upload in SPPA-T3000 Application Server","id":"CVE-2019-18288","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":7.5,"headline":"Denial of service in SPPA-T3000 Application Server","id":"CVE-2019-18317","kev_date_added":null,"published":"2019-12-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Siemens"]},"summary":"An attacker with network access can view directory listings on the SPPA-T3000 Application Server by sending crafted packets to specific ports.","url":"https://insights.sbomify.com/CVE-2019-18332/"}