CVE-2019-18338 Path traversal in Control Center Server (CCS)

High 7.7 Published Updated

An authenticated remote attacker can exploit a directory traversal flaw in Siemens Control Center Server to list arbitrary directories and read files outside the application context.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2019-18338?

CVE-2019-18338 is a high-severity path traversal vulnerability in Siemens Control Center Server (CCS), published on 12 Dec 2019. Any signed-in user can exploit it over the network, with no action from the victim.

Official description

A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains a directory traversal vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp.

An authenticated remote attacker with network access to the CCS server could exploit this vulnerability to list arbitrary directories or read files outside of the CCS application context.

Weakness: CWE-22, CWE-23

Which versions are affected by CVE-2019-18338?

It affects 2 products.

Products include Siemens Sinvr 3 Central Control Server, Siemens Sinvr 3 Video Server.

How do I fix CVE-2019-18338?

No fix has been published for CVE-2019-18338 yet. Limit exposure of the affected software until one is available.

Upgrade, and resolve every user-supplied path against an allowed base folder before opening it. More about Path traversal.

Is CVE-2019-18338 being exploited?

There is no known exploitation of CVE-2019-18338 in the wild and no public exploit code.

Sources

Also known as GHSA-q9wr-9rpv-8m6q.

Is CVE-2019-18338 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free