{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2019-18340 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-18340 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-18340 is a medium-severity vulnerability in Siemens Control Center Server (CCS), published on 12 Dec 2019. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-18340 and fix it if it is affected.\n\nWhat it is: CVE-2019-18340 is a medium-severity vulnerability in Siemens Control Center Server (CCS), published on 12 Dec 2019. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-18340 in the wild and no public exploit code.\n\nAffected product: Siemens Control Center Server (CCS). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-18340/ (Markdown: https://insights.sbomify.com/CVE-2019-18340/index.md)","id":"CVE-2019-18340","markdown":"https://insights.sbomify.com/CVE-2019-18340/index.md","name":"CVE-2019-18340","record":{"aliases":["GHSA-9mrf-w63c-fxfh"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read","account_takeover"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens video server","requires_auth":"low_privilege","summary":"A local attacker can extract user and device passwords from Siemens video servers due to weak cryptography, enabling further attacks.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sinvr_3_central_control_server","vendor":"siemens"},{"product":"sinvr_3_video_server","vendor":"siemens"}],"cvss":{"score":5.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N/E:F/RL:U/RC:C","version":"3.1"},"cwes":[{"id":"CWE-327","name":"Use of a Broken or Risky Cryptographic Algorithm"}],"description":"A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0), Control Center Server (CCS) (All versions \u003e= V1.5.0), SiNVR/SiVMS Video Server (All versions \u003c V5.0.0), SiNVR/SiVMS Video Server (All versions \u003e= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store\nuser and device passwords by applying weak cryptography.\n\nA local attacker could exploit this vulnerability to extract\nthe passwords from the user database and/or the device configuration files\nto conduct further attacks.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Weak cryptography in Control Center Server (CCS)","id":"CVE-2019-18340","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Auth bypass in Control Center Server (CCS)","id":"CVE-2019-18341"},"packages":[],"prev":{"headline":"Auth bypass in SiNVR/SiVMS Video Server","id":"CVE-2019-18339"},"products":["Control Center Server (CCS)","SiNVR/SiVMS Video Server"],"published":"2019-12-12","related":[{"cvss_score":9.8,"headline":"Auth bypass in Control Center Server (CCS)","id":"CVE-2019-18337","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Auth bypass in SiNVR/SiVMS Video Server","id":"CVE-2019-18339","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":8.8,"headline":"SQL injection in Control Center Server (CCS)","id":"CVE-2019-19292","kev_date_added":null,"published":"2020-03-10"},{"cvss_score":7.7,"headline":"Path traversal in Control Center Server (CCS)","id":"CVE-2019-18338","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":7.5,"headline":"Path traversal in SiNVR/SiVMS Video Server","id":"CVE-2019-19297","kev_date_added":null,"published":"2020-03-10"},{"cvss_score":6.8,"headline":"Path traversal in SiNVR/SiVMS Video Server","id":"CVE-2019-19296","kev_date_added":null,"published":"2020-03-10"},{"cvss_score":6.5,"headline":"Path traversal in Control Center Server (CCS)","id":"CVE-2019-19290","kev_date_added":null,"published":"2020-03-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Siemens"]},"summary":"A local attacker can extract user and device passwords from Siemens video servers due to weak cryptography, enabling further attacks.","url":"https://insights.sbomify.com/CVE-2019-18340/"}