{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2019-18341 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-18341 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-18341 is a medium-severity authentication bypass vulnerability in Siemens Control Center Server (CCS), published on 12 Dec 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-18341 and fix it if it is affected.\n\nWhat it is: CVE-2019-18341 is a medium-severity authentication bypass vulnerability in Siemens Control Center Server (CCS), published on 12 Dec 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-18341 in the wild and no public exploit code.\n\nAffected product: Siemens Control Center Server (CCS). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-18341/ (Markdown: https://insights.sbomify.com/CVE-2019-18341/index.md)","id":"CVE-2019-18341","markdown":"https://insights.sbomify.com/CVE-2019-18341/index.md","name":"CVE-2019-18341","record":{"aliases":["GHSA-g28c-477m-v5p9"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens Control Center Server","requires_auth":"none","summary":"Remote attackers can bypass SFTP authentication to read sensitive configuration data from the Siemens Control Center Server.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sinvr_3_central_control_server","vendor":"siemens"},{"product":"sinvr_3_video_server","vendor":"siemens"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:F/RL:U/RC:C","version":"3.1"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"}],"description":"A vulnerability has been identified in Control Center Server (CCS) (All versions \u003c V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server\n(CCS) contains an authentication bypass vulnerability.\n\nA remote attacker with network access to the CCS server could\nexploit this vulnerability to read data from the EDIR directory\n(for example, the list of all configured stations).","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in Control Center Server (CCS)","id":"CVE-2019-18341","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Path traversal in Control Center Server (CCS)","id":"CVE-2019-18342"},"packages":[],"prev":{"headline":"Weak cryptography in Control Center Server (CCS)","id":"CVE-2019-18340"},"products":["Control Center Server (CCS)"],"published":"2019-12-12","related":[{"cvss_score":9.8,"headline":"Auth bypass in Control Center Server (CCS)","id":"CVE-2019-18337","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":9.8,"headline":"Auth bypass in SiNVR/SiVMS Video Server","id":"CVE-2019-18339","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":8.8,"headline":"SQL injection in Control Center Server (CCS)","id":"CVE-2019-19292","kev_date_added":null,"published":"2020-03-10"},{"cvss_score":7.7,"headline":"Path traversal in Control Center Server (CCS)","id":"CVE-2019-18338","kev_date_added":null,"published":"2019-12-12"},{"cvss_score":7.5,"headline":"Path traversal in SiNVR/SiVMS Video Server","id":"CVE-2019-19297","kev_date_added":null,"published":"2020-03-10"},{"cvss_score":6.8,"headline":"Path traversal in SiNVR/SiVMS Video Server","id":"CVE-2019-19296","kev_date_added":null,"published":"2020-03-10"},{"cvss_score":6.5,"headline":"Path traversal in Control Center Server (CCS)","id":"CVE-2019-19290","kev_date_added":null,"published":"2020-03-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-05","vendors":["Siemens"]},"summary":"Remote attackers can bypass SFTP authentication to read sensitive configuration data from the Siemens Control Center Server.","url":"https://insights.sbomify.com/CVE-2019-18341/"}