{"answers":{"affected":"","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2019-25322 exists.","fix":"No fix has been published for CVE-2019-25322 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-25322 is a critical vulnerability in Heatmiser Netmonitor, published on 12 Feb 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-25322 and fix it if it is affected.\n\nWhat it is: CVE-2019-25322 is a critical vulnerability in Heatmiser Netmonitor, published on 12 Feb 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2019-25322 exists.\n\nAffected product: Heatmiser Netmonitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-25322/ (Markdown: https://insights.sbomify.com/CVE-2019-25322/index.md)","id":"CVE-2019-25322","markdown":"https://insights.sbomify.com/CVE-2019-25322/index.md","name":"CVE-2019-25322","record":{"aliases":["GHSA-4mqf-r24p-f3vh"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["account_takeover","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Heatmiser Netmonitor","requires_auth":"none","summary":"Attackers can gain administrative access to Heatmiser Netmonitor devices using hardcoded default credentials, compromising device security.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[],"cvss":{"score":9.3,"severity":"critical","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"weaponised"},"has_fix":null,"headline":"Heatmiser Netmonitor 3.03 - Hardcoded Credentials","id":"CVE-2019-25322","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2019"},"n_packages":0,"n_references":4,"next":{"headline":"Heatmiser Netmonitor 3.03 - HTML Injection","id":"CVE-2019-25323"},"packages":[],"prev":{"headline":"FTP Navigator 8.03 - Stack Overflow (SEH)","id":"CVE-2019-25321"},"products":["Heatmiser Netmonitor"],"published":"2026-02-12","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"poc","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-02-13","vendors":["Heatmiser"]},"summary":"Attackers can gain administrative access to Heatmiser Netmonitor devices using hardcoded default credentials, compromising device security.","url":"https://insights.sbomify.com/CVE-2019-25322/"}