{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2019-25716 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-25716 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-25716 is a high-severity denial of service vulnerability in Dräger Infinity Delta, published on 1 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-25716 and fix it if it is affected.\n\nWhat it is: CVE-2019-25716 is a high-severity denial of service vulnerability in Dräger Infinity Delta, published on 1 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-25716 in the wild and no public exploit code.\n\nAffected product: Dräger Infinity Delta. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-25716/ (Markdown: https://insights.sbomify.com/CVE-2019-25716/index.md)","id":"CVE-2019-25716","markdown":"https://insights.sbomify.com/CVE-2019-25716/index.md","name":"CVE-2019-25716","record":{"aliases":["GHSA-x6h5-p8qf-9j76"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"patient monitor","requires_auth":"none","summary":"Remote attackers can cause Dräger patient monitors to reboot and lose connectivity by sending malformed network packets, disrupting patient monitoring.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[{"product":"delta_xl_firmware","vendor":"draeger"},{"product":"infinity_delta_firmware","vendor":"draeger"},{"product":"kappa_firmware","vendor":"draeger"}],"cvss":{"score":7.1,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-15","name":"External Control of System or Configuration Setting"}],"description":"Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause the monitor to reboot by sending a malformed network packet. Attackers can repeatedly send malformed network packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet","id":"CVE-2019-25716","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure","id":"CVE-2019-25717"},"packages":[],"prev":{"headline":"This CVE ID has been rejected or withdrawn by its CVE Numbering Authority.","id":"CVE-2019-25715"},"products":["Infinity Delta","Infinity Delta XL","Infinity Kappa"],"published":"2026-06-01","related":[{"cvss_score":7.8,"headline":"Security feature bypass in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19012","kev_date_added":null,"published":"2019-01-28"},{"cvss_score":6.5,"headline":"Denial of service in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19010","kev_date_added":null,"published":"2019-01-28"},{"cvss_score":6.5,"headline":"Information disclosure in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19014","kev_date_added":null,"published":"2019-01-28"},{"cvss_score":5.3,"headline":"Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure","id":"CVE-2019-25717","kev_date_added":null,"published":"2026-06-02"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-07-15","vendors":["Dräger"]},"summary":"Remote attackers can cause Dräger patient monitors to reboot and lose connectivity by sending malformed network packets, disrupting patient monitoring.","url":"https://insights.sbomify.com/CVE-2019-25716/"}