{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2019-25717 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-25717 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-25717 is a medium-severity vulnerability in Dräger Infinity Delta, published on 2 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-25717 and fix it if it is affected.\n\nWhat it is: CVE-2019-25717 is a medium-severity vulnerability in Dräger Infinity Delta, published on 2 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-25717 in the wild and no public exploit code.\n\nAffected product: Dräger Infinity Delta. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-25717/ (Markdown: https://insights.sbomify.com/CVE-2019-25717/index.md)","id":"CVE-2019-25717","markdown":"https://insights.sbomify.com/CVE-2019-25717/index.md","name":"CVE-2019-25717","record":{"aliases":["GHSA-pch2-3675-w238"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Patient monitor","requires_auth":"none","summary":"Unauthenticated attackers can access log files on Dräger patient monitors, exposing device internals and network configuration details.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[{"product":"delta_xl_firmware","vendor":"draeger"},{"product":"infinity_delta_firmware","vendor":"draeger"},{"product":"kappa_firmware","vendor":"draeger"}],"cvss":{"score":5.3,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-538","name":"Insertion of Sensitive Information into Externally-Accessible File or Directory"}],"description":"Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated network attackers to access log files over a network connection. Attackers can retrieve device internals, location information, and wired network configuration details from the exposed log files.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure","id":"CVE-2019-25717","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass","id":"CVE-2019-25718"},"packages":[],"prev":{"headline":"Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet","id":"CVE-2019-25716"},"products":["Infinity Delta","Infinity Delta XL","Infinity Kappa"],"published":"2026-06-02","related":[{"cvss_score":7.8,"headline":"Security feature bypass in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19012","kev_date_added":null,"published":"2019-01-28"},{"cvss_score":7.1,"headline":"Dräger Infinity Delta/Kappa Patient Monitor DoS via Malformed Network Packet","id":"CVE-2019-25716","kev_date_added":null,"published":"2026-06-01"},{"cvss_score":6.5,"headline":"Denial of service in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19010","kev_date_added":null,"published":"2019-01-28"},{"cvss_score":6.5,"headline":"Information disclosure in Dr\u0026#195;\u0026#164;ger Infinity Delta","id":"CVE-2018-19014","kev_date_added":null,"published":"2019-01-28"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-07-15","vendors":["Dräger"]},"summary":"Unauthenticated attackers can access log files on Dräger patient monitors, exposing device internals and network configuration details.","url":"https://insights.sbomify.com/CVE-2019-25717/"}