{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-25718 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-25718 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-25718 is a high-severity vulnerability in Dräger Infinity Explorer C700, published on 1 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-25718 and fix it if it is affected.\n\nWhat it is: CVE-2019-25718 is a high-severity vulnerability in Dräger Infinity Explorer C700, published on 1 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-25718 in the wild and no public exploit code.\n\nAffected product: Dräger Infinity Explorer C700. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-25718/ (Markdown: https://insights.sbomify.com/CVE-2019-25718/index.md)","id":"CVE-2019-25718","markdown":"https://insights.sbomify.com/CVE-2019-25718/index.md","name":"CVE-2019-25718","record":{"aliases":["GHSA-gv7p-xf8g-c233"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["privilege_escalation","code_execution"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical device","requires_auth":"none","summary":"Attackers can bypass kiosk mode on Dräger Infinity Explorer C700 to access the underlying OS, potentially taking control of the device and disrupting patient monitoring.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[{"product":"infinity_explorer_c700_firmware","vendor":"draeger"}],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-451","name":"User Interface (UI) Misrepresentation of Critical Information"}],"description":"Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the underlying operating system through a specific dialog interaction. Attackers can exploit this kiosk escape to take control of the operating system and cause the device to display incorrect or no information from the connected Delta Family patient monitor.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass","id":"CVE-2019-25718","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling","id":"CVE-2019-25719"},"packages":[],"prev":{"headline":"Dräger Infinity Delta/Kappa Patient Monitors Unauthenticated Log File Disclosure","id":"CVE-2019-25717"},"products":["Infinity Explorer C700"],"published":"2026-06-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-07-15","vendors":["Dräger"]},"summary":"Attackers can bypass kiosk mode on Dräger Infinity Explorer C700 to access the underlying OS, potentially taking control of the device and disrupting patient monitoring.","url":"https://insights.sbomify.com/CVE-2019-25718/"}