{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2019-25719 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-25719 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-25719 is a high-severity vulnerability in Dräger Infinity Acute Care System, published on 2 Jun 2026. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-25719 and fix it if it is affected.\n\nWhat it is: CVE-2019-25719 is a high-severity vulnerability in Dräger Infinity Acute Care System, published on 2 Jun 2026. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-25719 in the wild and no public exploit code.\n\nAffected product: Dräger Infinity Acute Care System. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-25719/ (Markdown: https://insights.sbomify.com/CVE-2019-25719/index.md)","id":"CVE-2019-25719","markdown":"https://insights.sbomify.com/CVE-2019-25719/index.md","name":"CVE-2019-25719","record":{"aliases":["GHSA-hxqp-hf33-px7g"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_modify","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"patient monitor","requires_auth":"none","summary":"Network-adjacent attackers can spoof data, modify alarm settings, and cause denial-of-service on Dräger Infinity patient monitors.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-924","name":"Improper Enforcement of Message Integrity During Transmission in a Communication Channel"}],"description":"Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contain network message handling vulnerabilities that allow network-adjacent attackers to spoof or tamper with data and cause denial-of-service conditions. Attackers with access to an enabled Infinity network port or physical proximity to a wireless access point can modify device settings such as alarm states or alarm limits, and overwhelm the system with incoming data causing the device to reboot and lose network functionality.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling","id":"CVE-2019-25719","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Dräger SC Monitoring Devices DoS via Malformed Network Packet","id":"CVE-2019-25720"},"packages":[],"prev":{"headline":"Dräger Infinity Explorer C700 Privilege Escalation via Kiosk Mode Bypass","id":"CVE-2019-25718"},"products":["Infinity Acute Care System","Standalone Infinity M540 patient monitor"],"published":"2026-06-02","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-06-03","vendors":["Dräger"]},"summary":"Network-adjacent attackers can spoof data, modify alarm settings, and cause denial-of-service on Dräger Infinity patient monitors.","url":"https://insights.sbomify.com/CVE-2019-25719/"}