{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2019-25720 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-25720 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-25720 is a high-severity denial of service vulnerability in Dräger SC 6002XL, published on 3 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-25720 and fix it if it is affected.\n\nWhat it is: CVE-2019-25720 is a high-severity denial of service vulnerability in Dräger SC 6002XL, published on 3 Jun 2026. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-25720 in the wild and no public exploit code.\n\nAffected product: Dräger SC 6002XL. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-25720/ (Markdown: https://insights.sbomify.com/CVE-2019-25720/index.md)","id":"CVE-2019-25720","markdown":"https://insights.sbomify.com/CVE-2019-25720/index.md","name":"CVE-2019-25720","record":{"aliases":["GHSA-4wcc-pjv3-vvw7"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical monitoring device","requires_auth":"none","summary":"Unauthenticated attackers can reboot Dräger SC monitoring devices by sending malformed network packets, disrupting patient monitoring.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"VulnCheck","cpe":[],"cvss":{"score":7.1,"severity":"high","source":"cna","vector":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-1286","name":"Improper Validation of Syntactic Correctness of Input"}],"description":"Dräger SC Monitoring devices (SC 6002XL, SC 6802XL, SC 7000, SC 8000, SC 9000 XL) contain a denial-of-service vulnerability in all software versions that allows unauthenticated attackers to reboot the monitor by sending a malformed network packet. Attackers can repeatedly send such malformed packets to disrupt patient monitoring until the device falls back to default configuration and loses network connectivity.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Dräger SC Monitoring Devices DoS via Malformed Network Packet","id":"CVE-2019-25720","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Dräger Infinity M300 VG2.3.1 Network-Based Denial of Service","id":"CVE-2019-25721"},"packages":[],"prev":{"headline":"Dräger Infinity M540 VG4.1.1 Spoofing and DoS via Network Message Handling","id":"CVE-2019-25719"},"products":["SC 6002XL","SC 7000","SC6802XL","SC8000","SC90000 XL"],"published":"2026-06-03","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2026-06-03","vendors":["Dräger"]},"summary":"Unauthenticated attackers can reboot Dräger SC monitoring devices by sending malformed network packets, disrupting patient monitoring.","url":"https://insights.sbomify.com/CVE-2019-25720/"}