{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-3975 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-3975 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-3975 is a critical memory corruption vulnerability in Advantech Webaccess, published on 10 Sep 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-3975 and fix it if it is affected.\n\nWhat it is: CVE-2019-3975 is a critical memory corruption vulnerability in Advantech Webaccess, published on 10 Sep 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-3975 in the wild and no public exploit code.\n\nAffected product: Advantech Webaccess. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-3975/ (Markdown: https://insights.sbomify.com/CVE-2019-3975/index.md)","id":"CVE-2019-3975","markdown":"https://insights.sbomify.com/CVE-2019-3975/index.md","name":"CVE-2019-3975","record":{"aliases":["GHSA-j59w-xv7q-cp8v"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA software","requires_auth":"none","summary":"Remote unauthenticated attackers can execute arbitrary code on Advantech WebAccess/SCADA systems via a crafted RPC message.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"tenable","cpe":[{"product":"webaccess","vendor":"advantech"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"}],"description":"Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.1 allows a remote, unauthenticated attacker to execute arbitrary code via a crafted IOCTL 70603 RPC message.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in WebAccess/SCADA","id":"CVE-2019-3975","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"advantech:webaccess","products":["advantech:webaccess"],"type":"memory_corruption","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in MikroTik RouterOS","id":"CVE-2019-3976"},"packages":[],"prev":{"headline":"Path traversal in Tenable Nessus","id":"CVE-2019-3974"},"products":["WebAccess/SCADA"],"published":"2019-09-10","related":[{"cvss_score":10,"headline":"Multiple stack-based buffer overflows in unspecified DLL files in Advantech WebAccess before 8.0.1 allow remote attackers to execute arbitra","id":"CVE-2014-9208","kev_date_added":null,"published":"2015-09-11"},{"cvss_score":9.8,"headline":"Advantech WebAccess","id":"CVE-2021-33023","kev_date_added":null,"published":"2021-10-18"},{"cvss_score":9.8,"headline":"Advantech WebAccess","id":"CVE-2021-38389","kev_date_added":null,"published":"2021-10-18"},{"cvss_score":9.8,"headline":"Memory corruption in Advantech WebAccess","id":"CVE-2021-38408","kev_date_added":null,"published":"2021-09-09"},{"cvss_score":9.8,"headline":"Memory corruption in WebAccess Node","id":"CVE-2020-12019","kev_date_added":null,"published":"2020-06-15"},{"cvss_score":9.8,"headline":"Memory corruption in Advantech WebAccess Node","id":"CVE-2020-10638","kev_date_added":null,"published":"2020-05-08"},{"cvss_score":9.8,"headline":"Memory corruption in Advantech WebAccess Node","id":"CVE-2020-12002","kev_date_added":null,"published":"2020-05-08"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Advantech"]},"summary":"Remote unauthenticated attackers can execute arbitrary code on Advantech WebAccess/SCADA systems via a crafted RPC message.","url":"https://insights.sbomify.com/CVE-2019-3975/"}