{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-5640 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-5640 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-5640 is a low-severity vulnerability in Rapid7 Nexpose, published on 22 Nov 2021. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-5640 and fix it if it is affected.\n\nWhat it is: CVE-2019-5640 is a low-severity vulnerability in Rapid7 Nexpose, published on 22 Nov 2021. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-5640 in the wild and no public exploit code.\n\nAffected product: Rapid7 Nexpose. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-5640/ (Markdown: https://insights.sbomify.com/CVE-2019-5640/index.md)","id":"CVE-2019-5640","markdown":"https://insights.sbomify.com/CVE-2019-5640/index.md","name":"CVE-2019-5640","record":{"aliases":["GHSA-4jrr-pcvg-6fp6"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Vulnerability Management","requires_auth":"low_privilege","summary":"An attacker can view sensitive data from the previous user's session by removing the login panel via browser inspection after the session expires.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"rapid7","cpe":[{"product":"nexpose","vendor":"rapid7"}],"cvss":{"score":3.3,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"Rapid7 Nexpose versions prior to 6.6.114 suffer from an information exposure issue whereby, when the user's session has ended due to inactivity, an attacker can use the inspect element browser feature to remove the login panel and view the details available in the last webpage visited by previous user","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Rapid7 Nexpose Information Disclosure after logout","id":"CVE-2019-5640","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Rapid7 InsightVM Information Disclosure after Logout","id":"CVE-2019-5641"},"packages":[],"prev":{"headline":"Rapid7 Nexpose Insufficient Session Management","id":"CVE-2019-5638"},"products":["Nexpose"],"published":"2021-11-22","related":[{"cvss_score":8.8,"headline":"Cross-site request forgery in Nexpose","id":"CVE-2017-5264","kev_date_added":null,"published":"2017-12-14"},{"cvss_score":8.7,"headline":"Rapid7 Nexpose Insufficient Session Management","id":"CVE-2019-5638","kev_date_added":null,"published":"2019-08-21"},{"cvss_score":8.5,"headline":"Weak cryptography in Nexpose hardware appliance","id":"CVE-2017-5243","kev_date_added":null,"published":"2017-06-06"},{"cvss_score":7.8,"headline":"Other in Nexpose","id":"CVE-2017-5232","kev_date_added":null,"published":"2017-03-02"},{"cvss_score":7.2,"headline":"Hardcoded credentials in Nexpose","id":"CVE-2017-5230","kev_date_added":null,"published":"2017-03-02"},{"cvss_score":6.8,"headline":"Unquoted Path in Rapid7 Nexpose Installer","id":"CVE-2020-7382","kev_date_added":null,"published":"2020-09-03"},{"cvss_score":6.8,"headline":"Cross-site request forgery in n/a","id":"CVE-2012-6493","kev_date_added":null,"published":"2014-02-04"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Rapid7"]},"summary":"An attacker can view sensitive data from the previous user's session by removing the login panel via browser inspection after the session expires.","url":"https://insights.sbomify.com/CVE-2019-5640/"}