{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2019-6542 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-6542 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-6542 is a high-severity missing authorization vulnerability in ENTTEC Datagate MK2, published on 28 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-6542 and fix it if it is affected.\n\nWhat it is: CVE-2019-6542 is a high-severity missing authorization vulnerability in ENTTEC Datagate MK2, published on 28 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-6542 in the wild and no public exploit code.\n\nAffected product: ENTTEC Datagate MK2. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-6542/ (Markdown: https://insights.sbomify.com/CVE-2019-6542/index.md)","id":"CVE-2019-6542","markdown":"https://insights.sbomify.com/CVE-2019-6542/index.md","name":"CVE-2019-6542","record":{"aliases":["GHSA-rg4v-m3x7-gg8h"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"ENTTEC lighting controller","requires_auth":"none","summary":"Unauthenticated attackers can remotely reboot ENTTEC lighting controllers, causing a denial of service condition.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"datagate_mk2_firmware","vendor":"enttec"},{"product":"pixelator_firmware","vendor":"enttec"},{"product":"storm_24_firmware","vendor":"enttec"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"ENTTEC Datagate MK2, Storm 24, Pixelator all firmware versions prior to (70044,70050,70060)_update_05032019-482 allows an unauthenticated user to initiate a remote reboot, which may be used to cause a denial of service condition.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in Datagate MK2","id":"CVE-2019-6542","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update","id":"CVE-2019-6543"},"packages":[],"prev":{"headline":"Memory corruption in WECON LeviStudioU","id":"CVE-2019-6541"},"products":["Datagate MK2","Pixelator","Storm 24"],"published":"2019-03-28","related":[{"cvss_score":9.8,"headline":"Hardcoded credentials in n/a","id":"CVE-2019-12776","kev_date_added":null,"published":"2019-06-07"},{"cvss_score":8.8,"headline":"Privilege escalation in n/a","id":"CVE-2019-12775","kev_date_added":null,"published":"2019-06-07"},{"cvss_score":7.8,"headline":"Misconfiguration in n/a","id":"CVE-2019-12777","kev_date_added":null,"published":"2019-06-07"},{"cvss_score":6.1,"headline":"Cross-site scripting in n/a","id":"CVE-2019-12774","kev_date_added":null,"published":"2019-06-07"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["ENTTEC"]},"summary":"Unauthenticated attackers can remotely reboot ENTTEC lighting controllers, causing a denial of service condition.","url":"https://insights.sbomify.com/CVE-2019-6542/"}