{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-6548 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-6548 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-6548 is a critical vulnerability in GE Communicator, published on 9 May 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-6548 and fix it if it is affected.\n\nWhat it is: CVE-2019-6548 is a critical vulnerability in GE Communicator, published on 9 May 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-6548 in the wild and no public exploit code.\n\nAffected product: GE Communicator. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-6548/ (Markdown: https://insights.sbomify.com/CVE-2019-6548/index.md)","id":"CVE-2019-6548","markdown":"https://insights.sbomify.com/CVE-2019-6548/index.md","name":"CVE-2019-6548","record":{"aliases":["GHSA-w27f-jh8g-p7vw"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"GE Communicator","requires_auth":"none","summary":"Hardcoded backdoor accounts in GE Communicator allow attackers to control the database, posing a risk to industrial control systems.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"ge_communicator","vendor":"ge"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the database. This service is inaccessible to attackers if Windows default firewall settings are used by the end user.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in GE Communicator","id":"CVE-2019-6548","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in PR100088 Modbus gateway","id":"CVE-2019-6549"},"packages":[],"prev":{"headline":"Memory corruption in Delta Industrial Automation CNCSoft","id":"CVE-2019-6547"},"products":["GE Communicator"],"published":"2019-05-09","related":[{"cvss_score":7.8,"headline":"Path traversal in GE Communicator","id":"CVE-2019-6546","kev_date_added":null,"published":"2019-05-09"},{"cvss_score":7.8,"headline":"Privilege escalation in GE Communicator","id":"CVE-2019-6564","kev_date_added":null,"published":"2019-05-09"},{"cvss_score":7.8,"headline":"Privilege escalation in GE Communicator","id":"CVE-2019-6566","kev_date_added":null,"published":"2019-05-09"},{"cvss_score":7.6,"headline":"Memory corruption in GE Communicator","id":"CVE-2017-7908","kev_date_added":null,"published":"2018-10-02"},{"cvss_score":5.6,"headline":"Privilege escalation in GE Communicator","id":"CVE-2019-6544","kev_date_added":null,"published":"2019-05-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Hardcoded backdoor accounts in GE Communicator allow attackers to control the database, posing a risk to industrial control systems.","url":"https://insights.sbomify.com/CVE-2019-6548/"}