{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2019-6569 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-6569 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-6569 is a critical vulnerability in Siemens SCALANCE X204-2, published on 26 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-6569 and fix it if it is affected.\n\nWhat it is: CVE-2019-6569 is a critical vulnerability in Siemens SCALANCE X204-2, published on 26 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-6569 in the wild and no public exploit code.\n\nAffected product: Siemens SCALANCE X204-2. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-6569/ (Markdown: https://insights.sbomify.com/CVE-2019-6569/index.md)","id":"CVE-2019-6569","markdown":"https://insights.sbomify.com/CVE-2019-6569/index.md","name":"CVE-2019-6569","record":{"aliases":["GHSA-pq3w-wpr9-q68m"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["data_modify","other"],"network_reachable":"yes","non_default_config":true,"product_category":"Industrial Ethernet Switch","requires_auth":"none","summary":"Attackers can bypass monitor barriers to inject malicious packets into mirrored networks, potentially altering system configuration and runtime behavior.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"scalance_x-200_firmware","vendor":"siemens"},{"product":"scalance_x-300_firmware","vendor":"siemens"},{"product":"scalance_xc-200_firmware","vendor":"siemens"},{"product":"scalance_xf-200_firmware","vendor":"siemens"},{"product":"scalance_xp-200_firmware","vendor":"siemens"}],"cvss":{"score":9.1,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-440","name":"Expected Behavior Violation"}],"description":"The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in SCALANCE X204-2","id":"CVE-2019-6569","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in SINEMA Remote Connect Server","id":"CVE-2019-6570"},"packages":[],"prev":{"headline":"Denial of service in SIMATIC CP 1604","id":"CVE-2019-6568"},"products":["SCALANCE X204-2","SCALANCE X204-2FM","SCALANCE X204-2LD","SCALANCE X204-2LD TS","SCALANCE X204-2TS","SCALANCE X206-1","SCALANCE X206-1LD","SCALANCE X208","SCALANCE X208PRO","SCALANCE X212-2","SCALANCE X212-2LD","SCALANCE X216","SCALANCE X224","SCALANCE X302-7 EEC (230V)","SCALANCE X302-7 EEC (230V, coated)","SCALANCE X302-7 EEC (24V)","SCALANCE X302-7 EEC (24V, coated)","SCALANCE X302-7 EEC (2x 230V)","SCALANCE X302-7 EEC (2x 230V, coated)","SCALANCE X302-7 EEC (2x 24V)","SCALANCE X302-7 EEC (2x 24V, coated)","SCALANCE X304-2FE","SCALANCE X306-1LD FE","SCALANCE X307-2 EEC (230V)","SCALANCE X307-2 EEC (230V, coated)","SCALANCE X307-2 EEC (24V)","SCALANCE X307-2 EEC (24V, coated)","SCALANCE X307-2 EEC (2x 230V)","SCALANCE X307-2 EEC (2x 230V, coated)","SCALANCE X307-2 EEC (2x 24V)","SCALANCE X307-2 EEC (2x 24V, coated)","SCALANCE X307-3","SCALANCE X307-3LD","SCALANCE X308-2","SCALANCE X308-2LD","SCALANCE X308-2LH","SCALANCE X308-2LH+","SCALANCE X308-2M","SCALANCE X308-2M PoE","SCALANCE X308-2M TS","SCALANCE X310","SCALANCE X310FE","SCALANCE X320-1 FE","SCALANCE X320-1-2LD FE","SCALANCE X408-2","SCALANCE XB205-3 (SC)","SCALANCE XB205-3 (ST/BFOC)","SCALANCE XB205-3LD","SCALANCE XB208","SCALANCE XB213-3 (SC)","SCALANCE XB213-3 (ST/BFOC)","SCALANCE XB213-3LD","SCALANCE XB216","SCALANCE XC206-2 (SC)","SCALANCE XC206-2 (ST/BFOC)","SCALANCE XC206-2SFP","SCALANCE XC206-2SFP EEC","SCALANCE XC206-2SFP G","SCALANCE XC206-2SFP G EEC","SCALANCE XC208","SCALANCE XC208EEC","SCALANCE XC208G","SCALANCE XC208G EEC","SCALANCE XC216","SCALANCE XC216-4C","SCALANCE XC216-4C G","SCALANCE XC216-4C G (EIP Def.)","SCALANCE XC216-4C G EEC","SCALANCE XC216EEC","SCALANCE XC224","SCALANCE XC224-4C G","SCALANCE XC224-4C G (EIP Def.)","SCALANCE XC224-4C G EEC","SCALANCE XF204","SCALANCE XF204 DNA","SCALANCE XF204-2","SCALANCE XF204-2BA","SCALANCE XF204-2BA DNA","SCALANCE XF206-1","SCALANCE XF208","SCALANCE XP208","SCALANCE XP208EEC","SCALANCE XP208PoE EEC","SCALANCE XP216","SCALANCE XP216EEC","SCALANCE XP216POE EEC","SCALANCE XR324-12M (230V, ports on front)","SCALANCE XR324-12M (230V, ports on rear)","SCALANCE XR324-12M (24V, ports on front)","SCALANCE XR324-12M (24V, ports on rear)","SCALANCE XR324-12M TS (24V)","SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","SCALANCE XR324-4M EEC (24V, ports on front)","SCALANCE XR324-4M EEC (24V, ports on rear)","SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","SCALANCE XR324-4M EEC (2x 24V, ports on front)","SCALANCE XR324-4M EEC (2x 24V, ports on rear)","SCALANCE XR324-4M PoE (230V, ports on front)","SCALANCE XR324-4M PoE (230V, ports on rear)","SCALANCE XR324-4M PoE (24V, ports on front)","SCALANCE XR324-4M PoE (24V, ports on rear)","SCALANCE XR324-4M PoE TS (24V, ports on front)","SCALANCE XR324WG (24 X FE, DC 24V)","SCALANCE XR324WG (24 x FE, AC 230V)","SCALANCE XR328-4C WG (24XFE, 4XGE, 24V)","SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V)","SCALANCE XR328-4C WG (24xFE,4xGE,AC230V)","SCALANCE XR328-4C WG (28xGE, AC 230V)","SCALANCE XR328-4C WG (28xGE, DC 24V)","SIPLUS NET SCALANCE X308-2","SIPLUS NET SCALANCE XC206-2","SIPLUS NET SCALANCE XC206-2SFP","SIPLUS NET SCALANCE XC208","SIPLUS NET SCALANCE XC216-4C"],"published":"2019-03-26","related":[{"cvss_score":8.6,"headline":"Denial of service in SCALANCE X-200 switch family (incl. SIPLUS NET variants)","id":"CVE-2019-10942","kev_date_added":null,"published":"2019-08-13"},{"cvss_score":6.1,"headline":"Cross-site scripting in SCALANCE X-200 switch family (incl. SIPLUS NET variants)","id":"CVE-2018-4848","kev_date_added":null,"published":"2018-06-14"},{"cvss_score":5.5,"headline":"Information disclosure in SCALANCE X-200 switch family (incl. SIPLUS NET variants)","id":"CVE-2019-6567","kev_date_added":null,"published":"2019-06-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens"]},"summary":"Attackers can bypass monitor barriers to inject malicious packets into mirrored networks, potentially altering system configuration and runtime behavior.","url":"https://insights.sbomify.com/CVE-2019-6569/"}