{"answers":{"affected":"It affects 12 products.","exploited":"There is no known exploitation of CVE-2019-6572 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-6572 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-6572 is a critical vulnerability in Siemens AG SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel), published on 14 May 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-6572 and fix it if it is affected.\n\nWhat it is: CVE-2019-6572 is a critical vulnerability in Siemens AG SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel), published on 14 May 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-6572 in the wild and no public exploit code.\n\nAffected product: Siemens AG SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-6572/ (Markdown: https://insights.sbomify.com/CVE-2019-6572/index.md)","id":"CVE-2019-6572","markdown":"https://insights.sbomify.com/CVE-2019-6572/index.md","name":"CVE-2019-6572","record":{"aliases":["GHSA-q833-7p8r-rcqc"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens HMI Panels","requires_auth":"none","summary":"Attackers can read and modify data on Siemens HMI panels via SNMP due to a publicly known hardcoded community string.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"simatic_hmi_comfort_outdoor_panels_firmware","vendor":"siemens"},{"product":"simatic_hmi_comfort_panels_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp400f_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp700_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp700f_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp900_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp900f_firmware","vendor":"siemens"},{"product":"simatic_hmi_mp_firmware","vendor":"siemens"},{"product":"simatic_hmi_op_firmware","vendor":"siemens"},{"product":"simatic_hmi_tp_firmware","vendor":"siemens"},{"product":"simatic_wincc_\\(tia_portal\\)","vendor":"siemens"},{"product":"simatic_wincc_runtime","vendor":"siemens"}],"cvss":{"score":9.1,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"},{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2019-6572","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2019"},"n_packages":0,"n_references":3,"next":{"headline":"Denial of service in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...-","id":"CVE-2019-6574"},"packages":[],"prev":{"headline":"Denial of service in SIEMENS LOGO!8","id":"CVE-2019-6571"},"products":["SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"","SIMATIC HMI Comfort Panels 4\" - 22\"","SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F","SIMATIC WinCC (TIA Portal)","SIMATIC WinCC Runtime Advanced","SIMATIC WinCC Runtime Professional"],"published":"2019-05-14","related":[{"cvss_score":8.8,"headline":"Other in SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2018-13814","kev_date_added":null,"published":"2018-12-13"},{"cvss_score":8.1,"headline":"Open redirect in SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2018-13813","kev_date_added":null,"published":"2018-12-13"},{"cvss_score":7.5,"headline":"Path traversal in SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2018-13812","kev_date_added":null,"published":"2018-12-13"},{"cvss_score":6.5,"headline":"Weak cryptography in SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2019-6576","kev_date_added":null,"published":"2019-05-14"},{"cvss_score":5.4,"headline":"Cross-site scripting in SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2019-6577","kev_date_added":null,"published":"2019-05-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens AG"]},"summary":"Attackers can read and modify data on Siemens HMI panels via SNMP due to a publicly known hardcoded community string.","url":"https://insights.sbomify.com/CVE-2019-6572/"}