{"answers":{"affected":"It affects 12 products.","exploited":"There is no known exploitation of CVE-2019-6577 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-6577 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-6577 is a medium-severity cross-site scripting vulnerability in Siemens AG SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel), published on 14 May 2019. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2019-6577 and fix it if it is affected.\n\nWhat it is: CVE-2019-6577 is a medium-severity cross-site scripting vulnerability in Siemens AG SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel), published on 14 May 2019. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2019-6577 in the wild and no public exploit code.\n\nAffected product: Siemens AG SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-6577/ (Markdown: https://insights.sbomify.com/CVE-2019-6577/index.md)","id":"CVE-2019-6577","markdown":"https://insights.sbomify.com/CVE-2019-6577/index.md","name":"CVE-2019-6577","record":{"aliases":["GHSA-cxq5-q43p-whjh"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens HMI panels","requires_auth":"low_privilege","summary":"An attacker with system privileges can inject scripts into the web server via SNMP configuration changes, compromising confidentiality and integrity.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"simatic_hmi_comfort_outdoor_panels_firmware","vendor":"siemens"},{"product":"simatic_hmi_comfort_panels_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp400f_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp700_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp700f_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp900_firmware","vendor":"siemens"},{"product":"simatic_hmi_ktp_mobile_panels_ktp900f_firmware","vendor":"siemens"},{"product":"simatic_hmi_mp_firmware","vendor":"siemens"},{"product":"simatic_hmi_op_firmware","vendor":"siemens"},{"product":"simatic_hmi_tp_firmware","vendor":"siemens"},{"product":"simatic_wincc_\\(tia_portal\\)","vendor":"siemens"},{"product":"simatic_wincc_runtime","vendor":"siemens"}],"cvss":{"score":5.4,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","version":"3.0"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"},{"id":"CWE-80","name":"Improper Neutralization of Script-Related HTML Tags in a Web Page"}],"description":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2019-6577","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2019"},"n_packages":0,"n_references":3,"next":{"headline":"Denial of service in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...-","id":"CVE-2019-6578"},"packages":[],"prev":{"headline":"Weak cryptography in SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2019-6576"},"products":["SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\"","SIMATIC HMI Comfort Panels 4\" - 22\"","SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F","SIMATIC WinCC (TIA Portal)","SIMATIC WinCC Runtime Advanced","SIMATIC WinCC Runtime Professional"],"published":"2019-05-14","related":[{"cvss_score":9.1,"headline":"Hardcoded credentials in SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2019-6572","kev_date_added":null,"published":"2019-05-14"},{"cvss_score":8.8,"headline":"Other in SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2018-13814","kev_date_added":null,"published":"2018-12-13"},{"cvss_score":8.1,"headline":"Open redirect in SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2018-13813","kev_date_added":null,"published":"2018-12-13"},{"cvss_score":7.5,"headline":"Path traversal in SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC WinCC Runtime Advanced, SIMATIC WinCC Runtime Professional, SIMATIC WinCC (TIA Portal), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2018-13812","kev_date_added":null,"published":"2018-12-13"},{"cvss_score":6.5,"headline":"Weak cryptography in SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)","id":"CVE-2019-6576","kev_date_added":null,"published":"2019-05-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens AG"]},"summary":"An attacker with system privileges can inject scripts into the web server via SNMP configuration changes, compromising confidentiality and integrity.","url":"https://insights.sbomify.com/CVE-2019-6577/"}