{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2019-6582 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-6582 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-6582 is a high-severity missing authorization vulnerability in Siemens AG Siveillance VMS 2017 R2, published on 12 Jun 2019. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-6582 and fix it if it is affected.\n\nWhat it is: CVE-2019-6582 is a high-severity missing authorization vulnerability in Siemens AG Siveillance VMS 2017 R2, published on 12 Jun 2019. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-6582 in the wild and no public exploit code.\n\nAffected product: Siemens AG Siveillance VMS 2017 R2. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-6582/ (Markdown: https://insights.sbomify.com/CVE-2019-6582/index.md)","id":"CVE-2019-6582","markdown":"https://insights.sbomify.com/CVE-2019-6582/index.md","name":"CVE-2019-6582","record":{"aliases":["GHSA-469h-vcwf-r2v3"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_modify","denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Video Management System","requires_auth":"low_privilege","summary":"An authenticated attacker can modify user-defined event properties without proper authorization, compromising data integrity and functionality availability in Siemens Siveillance VMS.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"siveillance_video_management_software_2017_r2","vendor":"siemens"},{"product":"siveillance_video_management_software_2018_r1","vendor":"siemens"},{"product":"siveillance_video_management_software_2018_r2","vendor":"siemens"},{"product":"siveillance_video_management_software_2018_r3","vendor":"siemens"},{"product":"siveillance_video_management_software_2019_r1","vendor":"siemens"}],"cvss":{"score":7.1,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L","version":"3.1"},"cwes":[{"id":"CWE-863","name":"Incorrect Authorization"},{"id":"CWE-285","name":"Improper Authorization"}],"description":"A vulnerability has been identified in Siveillance VMS 2017 R2 (All versions \u003c V11.2a), Siveillance VMS 2018 R1 (All versions \u003c V12.1a), Siveillance VMS 2018 R2 (All versions \u003c V12.2a), Siveillance VMS 2018 R3 (All versions \u003c V12.3a), Siveillance VMS 2019 R1 (All versions \u003c V13.1a). An attacker with network access to port 80/TCP can change user-defined event properties without proper authorization. The security vulnerability could be exploited by an authenticated attacker with network access to the affected service. No user interaction is required to exploit this security vulnerability. Successful exploitation compromises integrity of the user-defined event properties and the availability of corresponding functionality. At the time of advisory publication no public exploitation of this security vulnerability was known.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in Siveillance VMS 2017 R2","id":"CVE-2019-6582","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Security feature bypass in SIEMENS LOGO!8","id":"CVE-2019-6584"},"packages":[],"prev":{"headline":"Missing authorization in Siveillance VMS 2017 R2","id":"CVE-2019-6581"},"products":["Siveillance VMS 2017 R2","Siveillance VMS 2018 R1","Siveillance VMS 2018 R2","Siveillance VMS 2018 R3","Siveillance VMS 2019 R1"],"published":"2019-06-12","related":[{"cvss_score":9.8,"headline":"Missing authorization in Siveillance VMS 2017 R2","id":"CVE-2019-6580","kev_date_added":null,"published":"2019-06-12"},{"cvss_score":8.8,"headline":"Missing authorization in Siveillance VMS 2017 R2","id":"CVE-2019-6581","kev_date_added":null,"published":"2019-06-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Siemens AG"]},"summary":"An authenticated attacker can modify user-defined event properties without proper authorization, compromising data integrity and functionality availability in Siemens Siveillance VMS.","url":"https://insights.sbomify.com/CVE-2019-6582/"}