{"answers":{"affected":"It affects 11 products.","exploited":"There is no known exploitation of CVE-2019-6853 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-6853 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-6853 is a medium-severity cross-site scripting vulnerability in Schneider Electric Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702, published on 20 Nov 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2019-6853 and fix it if it is affected.\n\nWhat it is: CVE-2019-6853 is a medium-severity cross-site scripting vulnerability in Schneider Electric Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702, published on 20 Nov 2019. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2019-6853 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-6853/ (Markdown: https://insights.sbomify.com/CVE-2019-6853/index.md)","id":"CVE-2019-6853","markdown":"https://insights.sbomify.com/CVE-2019-6853/index.md","name":"CVE-2019-6853","record":{"aliases":["GHSA-pc4q-2v2h-h23c"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Building automation controller","requires_auth":"none","summary":"Cross-site scripting vulnerability in Andover Continuum web server allows attackers to execute arbitrary scripts in user browsers.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"andover_continuum_5720_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_5740_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9200_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9680_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9702_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9900_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9924_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9940_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_9941_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_bcx4040_firmware","vendor":"schneider-electric"},{"product":"andover_continuum_bcx9640_firmware","vendor":"schneider-electric"}],"cvss":{"score":6.1,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"A CWE-79: Failure to Preserve Web Page Structure vulnerability exists in Andover Continuum (models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702) , which could enable a successful Cross-site Scripting (XSS attack) when using the products web server.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702","id":"CVE-2019-6853","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)","id":"CVE-2019-6854"},"packages":[],"prev":{"headline":"Hardcoded credentials in Modicon Controllers (M340 CPUs, M340 communication modules, Premium CPUs, Premium communication modules, Quantum CPUs, Quantum communication modules - see security notification for specific versions)","id":"CVE-2019-6852"},"products":["Andover Continuum models 9680, 5740 and 5720, bCX4040, bCX9640, 9900, 9940, 9924 and 9702"],"published":"2019-11-20","related":[{"cvss_score":9.8,"headline":"Code injection in Andover Continuum (All versions)","id":"CVE-2020-7480","kev_date_added":null,"published":"2020-03-23"},{"cvss_score":6.1,"headline":"Cross-site scripting in Andover Continuum (All versions)","id":"CVE-2020-7481","kev_date_added":null,"published":"2020-03-23"},{"cvss_score":6.1,"headline":"Cross-site scripting in Andover Continuum (All versions)","id":"CVE-2020-7482","kev_date_added":null,"published":"2020-03-23"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["Schneider Electric"]},"summary":"Cross-site scripting vulnerability in Andover Continuum web server allows attackers to execute arbitrary scripts in user browsers.","url":"https://insights.sbomify.com/CVE-2019-6853/"}