{"answers":{"affected":"It affects 16 products.","exploited":"There is no known exploitation of CVE-2019-7225 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-7225 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-7225 is a high-severity vulnerability in n/a, published on 27 Jun 2019. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-7225 and fix it if it is affected.\n\nWhat it is: CVE-2019-7225 is a high-severity vulnerability in n/a, published on 27 Jun 2019. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-7225 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-7225/ (Markdown: https://insights.sbomify.com/CVE-2019-7225/index.md)","id":"CVE-2019-7225","markdown":"https://insights.sbomify.com/CVE-2019-7225/index.md","name":"CVE-2019-7225","record":{"aliases":["GHSA-qh2p-23vc-r8qp"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"ABB HMI components","requires_auth":"none","summary":"Hardcoded administrative credentials in ABB HMI components allow attackers to read/write configuration files and reset devices.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"cp620-web_firmware","vendor":"abb"},{"product":"cp620_firmware","vendor":"abb"},{"product":"cp630-web_firmware","vendor":"abb"},{"product":"cp630_firmware","vendor":"abb"},{"product":"cp635-b_firmware","vendor":"abb"},{"product":"cp635-web_firmware","vendor":"abb"},{"product":"cp635_firmware","vendor":"abb"},{"product":"cp651-web_firmware","vendor":"abb"},{"product":"cp651_firmware","vendor":"abb"},{"product":"cp661-web_firmware","vendor":"abb"},{"product":"cp661_firmware","vendor":"abb"},{"product":"cp665-web_firmware","vendor":"abb"},{"product":"cp665_firmware","vendor":"abb"},{"product":"cp676-web_firmware","vendor":"abb"},{"product":"cp676_firmware","vendor":"abb"},{"product":"pb610_firmware","vendor":"abb"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool \"Panel Builder 600\" to flash a new interface and Tags (MODBUS coils) mapping to the HMI. These credentials are the idal123 password for the IdalMaster account, and the exor password for the exor account. These credentials are used over both HTTP(S) and FTP. There is no option to disable or change these undocumented credentials. An attacker can use these credentials to login to ABB HMI to read/write HMI configuration files and also to reset the device. This affects ABB CP635 HMI, CP600 HMIClient, Panel Builder 600, IDAL FTP server, IDAL HTTP server, and multiple other HMI components.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in n/a","id":"CVE-2019-7225","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2019"},"n_packages":0,"n_references":5,"next":{"headline":"Auth bypass in n/a","id":"CVE-2019-7226"},"packages":[],"prev":{"headline":"Cross-site scripting in n/a","id":"CVE-2019-7223"},"products":["n/a"],"published":"2019-06-27","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Hardcoded administrative credentials in ABB HMI components allow attackers to read/write configuration files and reset devices.","url":"https://insights.sbomify.com/CVE-2019-7225/"}