{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-7668 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-7668 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-7668 is a critical vulnerability in n/a, published on 1 Jul 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-7668 and fix it if it is affected.\n\nWhat it is: CVE-2019-7668 is a critical vulnerability in n/a, published on 1 Jul 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-7668 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-7668/ (Markdown: https://insights.sbomify.com/CVE-2019-7668/index.md)","id":"CVE-2019-7668","markdown":"https://insights.sbomify.com/CVE-2019-7668/index.md","name":"CVE-2019-7668","record":{"aliases":["GHSA-8wcr-vx43-xmg6"],"analysis":{"component_type":"iot_embedded","fix_type":"configuration_change","impacts":["account_takeover","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"FlexAir ventilation system","requires_auth":"none","summary":"Attackers can access Prima Systems FlexAir devices using default credentials, potentially gaining unauthorized control over the ventilation system.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"flexair","vendor":"primasystems"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-1188","name":"Initialization of a Resource with an Insecure Default"}],"description":"Prima Systems FlexAir devices have Default Credentials.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in n/a","id":"CVE-2019-7668","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"File upload in n/a","id":"CVE-2019-7669"},"packages":[],"prev":{"headline":"Information disclosure in n/a","id":"CVE-2019-7667"},"products":["n/a"],"published":"2019-07-01","related":[{"cvss_score":9.8,"headline":"Information disclosure in n/a","id":"CVE-2019-7667","kev_date_added":null,"published":"2019-07-01"},{"cvss_score":9,"headline":"Cross-site scripting in n/a","id":"CVE-2019-7671","kev_date_added":null,"published":"2019-06-05"},{"cvss_score":8.8,"headline":"Auth bypass in n/a","id":"CVE-2019-7280","kev_date_added":null,"published":"2019-07-01"},{"cvss_score":8.8,"headline":"Cross-site request forgery in n/a","id":"CVE-2019-7281","kev_date_added":null,"published":"2019-07-01"},{"cvss_score":8.8,"headline":"Auth bypass in n/a","id":"CVE-2019-7666","kev_date_added":null,"published":"2019-07-01"},{"cvss_score":8.8,"headline":"File upload in n/a","id":"CVE-2019-7669","kev_date_added":null,"published":"2019-07-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Attackers can access Prima Systems FlexAir devices using default credentials, potentially gaining unauthorized control over the ventilation system.","url":"https://insights.sbomify.com/CVE-2019-7668/"}