{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-7672 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-7672 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-7672 is a high-severity vulnerability in n/a, published on 5 Jun 2019. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-7672 and fix it if it is affected.\n\nWhat it is: CVE-2019-7672 is a high-severity vulnerability in n/a, published on 5 Jun 2019. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-7672 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-7672/ (Markdown: https://insights.sbomify.com/CVE-2019-7672/index.md)","id":"CVE-2019-7672","markdown":"https://insights.sbomify.com/CVE-2019-7672/index.md","name":"CVE-2019-7672","record":{"aliases":["GHSA-2fx6-86r8-c487"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"HVAC control system","requires_auth":"low_privilege","summary":"Hardcoded credentials in the FlexAir web interface allow authenticated attackers to escalate privileges within the HVAC control system.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"flexair","vendor":"primasystems"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in n/a","id":"CVE-2019-7672","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2019"},"n_packages":0,"n_references":4,"next":{"headline":"Weak cryptography in n/a","id":"CVE-2019-7673"},"packages":[],"prev":{"headline":"Cross-site scripting in n/a","id":"CVE-2019-7671"},"products":["n/a"],"published":"2019-06-05","related":[{"cvss_score":9.8,"headline":"Information disclosure in n/a","id":"CVE-2019-7667","kev_date_added":null,"published":"2019-07-01"},{"cvss_score":9.8,"headline":"Hardcoded credentials in n/a","id":"CVE-2019-7668","kev_date_added":null,"published":"2019-07-01"},{"cvss_score":9,"headline":"Cross-site scripting in n/a","id":"CVE-2019-7671","kev_date_added":null,"published":"2019-06-05"},{"cvss_score":8.8,"headline":"Auth bypass in n/a","id":"CVE-2019-7280","kev_date_added":null,"published":"2019-07-01"},{"cvss_score":8.8,"headline":"Cross-site request forgery in n/a","id":"CVE-2019-7281","kev_date_added":null,"published":"2019-07-01"},{"cvss_score":8.8,"headline":"Auth bypass in n/a","id":"CVE-2019-7666","kev_date_added":null,"published":"2019-07-01"},{"cvss_score":8.8,"headline":"File upload in n/a","id":"CVE-2019-7669","kev_date_added":null,"published":"2019-07-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Hardcoded credentials in the FlexAir web interface allow authenticated attackers to escalate privileges within the HVAC control system.","url":"https://insights.sbomify.com/CVE-2019-7672/"}