{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-7713 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-7713 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-7713 is a critical memory corruption vulnerability in n/a, published on 26 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-7713 and fix it if it is affected.\n\nWhat it is: CVE-2019-7713 is a critical memory corruption vulnerability in n/a, published on 26 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-7713 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-7713/ (Markdown: https://insights.sbomify.com/CVE-2019-7713/index.md)","id":"CVE-2019-7713","markdown":"https://insights.sbomify.com/CVE-2019-7713/index.md","name":"CVE-2019-7713","record":{"aliases":["GHSA-fjf5-84wj-9rcf"],"analysis":{"component_type":"operating_system","fix_type":"no_fix_stated","impacts":["denial_of_service","data_read"],"network_reachable":"yes","non_default_config":true,"product_category":"RTOS TELNET server","requires_auth":"none","summary":"Heap-based buffer overflow in Green Hills INTEGRITY RTOS TELNET server allows crashes and memory address leaks via custom prompt modifiers.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"integrity_rtos","vendor":"ghs"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"cwes":[{"id":"CWE-787","name":"Out-of-bounds Write"}],"description":"An issue was discovered in the Interpeak IPCOMShell TELNET server on Green Hills INTEGRITY RTOS 5.0.4. There is a heap-based buffer overflow in the function responsible for printing the shell prompt, when a custom modifier is used to display information such as a process ID, IP address, or current working directory. Modifier expansion triggers this overflow, causing memory corruption or a crash (and also leaks memory address information).","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in n/a","id":"CVE-2019-7713","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Memory corruption in n/a","id":"CVE-2019-7714"},"packages":[],"prev":{"headline":"Information disclosure in n/a","id":"CVE-2019-7712"},"products":["n/a"],"published":"2019-03-26","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2019-7714","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":7.5,"headline":"Information disclosure in n/a","id":"CVE-2019-7711","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":7.5,"headline":"Information disclosure in n/a","id":"CVE-2019-7712","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":7.5,"headline":"Information disclosure in n/a","id":"CVE-2019-7715","kev_date_added":null,"published":"2019-03-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Heap-based buffer overflow in Green Hills INTEGRITY RTOS TELNET server allows crashes and memory address leaks via custom prompt modifiers.","url":"https://insights.sbomify.com/CVE-2019-7713/"}