{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-7715 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-7715 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-7715 is a high-severity vulnerability in n/a, published on 26 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-7715 and fix it if it is affected.\n\nWhat it is: CVE-2019-7715 is a high-severity vulnerability in n/a, published on 26 Mar 2019. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-7715 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-7715/ (Markdown: https://insights.sbomify.com/CVE-2019-7715/index.md)","id":"CVE-2019-7715","markdown":"https://insights.sbomify.com/CVE-2019-7715/index.md","name":"CVE-2019-7715","record":{"aliases":["GHSA-5wmv-3f82-pww3"],"analysis":{"component_type":"operating_system","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"RTOS TELNET server","requires_auth":"none","summary":"A format string vulnerability in the INTEGRITY RTOS TELNET server allows attackers to leak memory addresses via a controlled environment variable.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"integrity_rtos","vendor":"ghs"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-134","name":"Use of Externally-Controlled Format String"}],"description":"An issue was discovered in the Interpeak IPCOMShell TELNET server on Green Hills INTEGRITY RTOS 5.0.4. The main shell handler function uses the value of the environment variable ipcom.shell.greeting as the first argument to printf(). Setting this variable using the sysvar command results in a user-controlled format string during login, resulting in an information leak of memory addresses.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2019-7715","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2019"},"n_packages":0,"n_references":2,"next":{"headline":"Race condition in n/a","id":"CVE-2019-7718"},"packages":[],"prev":{"headline":"Memory corruption in n/a","id":"CVE-2019-7714"},"products":["n/a"],"published":"2019-03-26","related":[{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2019-7713","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":9.8,"headline":"Memory corruption in n/a","id":"CVE-2019-7714","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":7.5,"headline":"Information disclosure in n/a","id":"CVE-2019-7711","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":7.5,"headline":"Information disclosure in n/a","id":"CVE-2019-7712","kev_date_added":null,"published":"2019-03-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"A format string vulnerability in the INTEGRITY RTOS TELNET server allows attackers to leak memory addresses via a controlled environment variable.","url":"https://insights.sbomify.com/CVE-2019-7715/"}