{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2019-9529 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-9529 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-9529 is a medium-severity missing authorization vulnerability in Cobham plc Explorer 710, published on 10 Oct 2019. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-9529 and fix it if it is affected.\n\nWhat it is: CVE-2019-9529 is a medium-severity missing authorization vulnerability in Cobham plc Explorer 710, published on 10 Oct 2019. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-9529 in the wild and no public exploit code.\n\nAffected product: Cobham plc Explorer 710. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-9529/ (Markdown: https://insights.sbomify.com/CVE-2019-9529/index.md)","id":"CVE-2019-9529","markdown":"https://insights.sbomify.com/CVE-2019-9529/index.md","name":"CVE-2019-9529","record":{"aliases":["GHSA-gc98-jrpr-jwqx"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["privilege_escalation","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Satellite terminal","requires_auth":"low_privilege","summary":"Unauthenticated local attackers can access the web portal and modify device settings due to missing default authentication.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"certcc","cpe":[{"product":"explorer_710_firmware","vendor":"cobham"}],"cvss":{"score":5.5,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"},{"id":"CWE-284","name":"Improper Access Control"}],"description":"The web application portal of the Cobham EXPLORER 710, firmware version 1.07, has no authentication by default. This could allow an unauthenticated, local attacker connected to the device to access the portal and to make any change to the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"The web application portal of the Cobham EXPLORER 710, firmware version 1.07, has no authentication by default","id":"CVE-2019-9529","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in Explorer 710","id":"CVE-2019-9530"},"packages":[],"prev":{"headline":"Some HTTP/2 implementations are vulnerable to a flood of empty frames, potentially leading to a denial of service","id":"CVE-2019-9518"},"products":["Explorer 710"],"published":"2019-10-10","related":[{"cvss_score":9.8,"headline":"Auth bypass in Explorer 710","id":"CVE-2019-9531","kev_date_added":null,"published":"2019-10-10"},{"cvss_score":9.8,"headline":"The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08","id":"CVE-2019-9533","kev_date_added":null,"published":"2019-10-10"},{"cvss_score":7.8,"headline":"The web application portal of the Cobham EXPLORER 710, firmware version 1.07, sends the login password in cleartext","id":"CVE-2019-9532","kev_date_added":null,"published":"2019-10-10"},{"cvss_score":7.8,"headline":"The Cobham EXPLORER 710, firmware version 1.07, does not validate its firmware image","id":"CVE-2019-9534","kev_date_added":null,"published":"2019-10-10"},{"cvss_score":5.5,"headline":"Missing authorization in Explorer 710","id":"CVE-2019-9530","kev_date_added":null,"published":"2019-10-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Cobham plc"]},"summary":"Unauthenticated local attackers can access the web portal and modify device settings due to missing default authentication.","url":"https://insights.sbomify.com/CVE-2019-9529/"}