{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2019-9862 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2019-9862 yet. Limit exposure of the affected software until one is available.","what":"CVE-2019-9862 is a medium-severity vulnerability in n/a, published on 27 Mar 2019. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2019-9862 and fix it if it is affected.\n\nWhat it is: CVE-2019-9862 is a medium-severity vulnerability in n/a, published on 27 Mar 2019. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2019-9862 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2019-9862/ (Markdown: https://insights.sbomify.com/CVE-2019-9862/index.md)","id":"CVE-2019-9862","markdown":"https://insights.sbomify.com/CVE-2019-9862/index.md","name":"CVE-2019-9862","record":{"aliases":["GHSA-6jm4-cmgj-f6fh"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"wireless alarm system","requires_auth":"none","summary":"Attackers can eavesdrop on cleartext wireless signals to steal sensitive data like rolling codes from ABUS Secvest alarm systems.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"secvest_wireless_alarm_system_fuaa50000_firmware","vendor":"abus"},{"product":"secvest_wireless_remote_control_fube50014_firmware","vendor":"abus"},{"product":"secvest_wireless_remote_control_fube50015_firmware","vendor":"abus"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"cwes":[{"id":"CWE-311","name":"Missing Encryption of Sensitive Data"}],"description":"An issue was discovered on ABUS Secvest wireless alarm system FUAA50000 3.01.01 in conjunction with Secvest remote control FUBE50014 or FUBE50015. Because \"encrypted signal transmission\" is missing, an attacker is able to eavesdrop sensitive data as cleartext (for instance, the current rolling code state).","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2019-9862","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2019"},"n_packages":0,"n_references":1,"next":{"headline":"Weak cryptography in n/a","id":"CVE-2019-9863"},"packages":[],"prev":{"headline":"Security feature bypass in n/a","id":"CVE-2019-9861"},"products":["n/a"],"published":"2019-03-27","related":[{"cvss_score":9.8,"headline":"Weak cryptography in n/a","id":"CVE-2019-9863","kev_date_added":null,"published":"2019-03-27"},{"cvss_score":8.1,"headline":"Security feature bypass in n/a","id":"CVE-2019-9861","kev_date_added":null,"published":"2019-05-14"},{"cvss_score":7.5,"headline":"Auth bypass in n/a","id":"CVE-2020-28973","kev_date_added":null,"published":"2021-04-21"},{"cvss_score":7.5,"headline":"Other in n/a","id":"CVE-2019-14261","kev_date_added":null,"published":"2019-09-03"},{"cvss_score":7.5,"headline":"Weak cryptography in n/a","id":"CVE-2019-9860","kev_date_added":null,"published":"2019-03-27"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Attackers can eavesdrop on cleartext wireless signals to steal sensitive data like rolling codes from ABUS Secvest alarm systems.","url":"https://insights.sbomify.com/CVE-2019-9862/"}