{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-10264 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-10264 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-10264 is a high-severity missing authorization vulnerability in Universal Robots Robot Controllers CB 3.1, published on 6 Apr 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-10264 and fix it if it is affected.\n\nWhat it is: CVE-2020-10264 is a high-severity missing authorization vulnerability in Universal Robots Robot Controllers CB 3.1, published on 6 Apr 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-10264 in the wild and no public exploit code.\n\nAffected product: Universal Robots Robot Controllers CB 3.1. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-10264/ (Markdown: https://insights.sbomify.com/CVE-2020-10264/index.md)","id":"CVE-2020-10264","markdown":"https://insights.sbomify.com/CVE-2020-10264/index.md","name":"CVE-2020-10264","record":{"aliases":["GHSA-hgj8-w26q-693m"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Universal Robots controller","requires_auth":"none","summary":"Attackers can read robot data and modify registers or outputs without authentication on Universal Robots controllers.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Alias","cpe":[{"product":"ur_software","vendor":"universal-robots"}],"cvss":{"score":8.8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"},{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"CB3 SW Version 3.3 and upwards, e-series SW Version 5.0 and upwards allow authenticated access to the RTDE (Real-Time Data Exchange) interface on port 30004 which allows setting registers, the speed slider fraction as well as digital and analog Outputs. Additionally unautheticated reading of robot data is also possible","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"RTDE Interface allows unauthenticated reading of robot data and unauthenticated writing of registers and outputs","id":"CVE-2020-10264","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions","id":"CVE-2020-10265"},"packages":[],"prev":{"headline":"Missing authorization in n/a","id":"CVE-2020-10263"},"products":["Universal Robots Robot Controllers CB 3.1","Universal Robots Robot Controllers e-Series"],"published":"2020-04-06","related":[{"cvss_score":9.4,"headline":"RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions","id":"CVE-2020-10265","kev_date_added":null,"published":"2020-04-06"},{"cvss_score":7.5,"headline":"RVD#1489: Unprotected intelectual property in Universal Robots controller CB 3.1 across firmware versions","id":"CVE-2020-10267","kev_date_added":null,"published":"2020-04-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Universal Robots A/S"]},"summary":"Attackers can read robot data and modify registers or outputs without authentication on Universal Robots controllers.","url":"https://insights.sbomify.com/CVE-2020-10264/"}