{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-10609 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-10609 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-10609 is a high-severity vulnerability in Grundfos CIM 500, published on 27 Jul 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-10609 and fix it if it is affected.\n\nWhat it is: CVE-2020-10609 is a high-severity vulnerability in Grundfos CIM 500, published on 27 Jul 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-10609 in the wild and no public exploit code.\n\nAffected product: Grundfos CIM 500. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-10609/ (Markdown: https://insights.sbomify.com/CVE-2020-10609/index.md)","id":"CVE-2020-10609","markdown":"https://insights.sbomify.com/CVE-2020-10609/index.md","name":"CVE-2020-10609","record":{"aliases":["GHSA-9482-q473-qwhj"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Grundfos CIM 500","requires_auth":"none","summary":"An attacker with device access can read plaintext credentials and modify system settings on Grundfos CIM 500 devices.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"cim_500","vendor":"grundfos"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-522","name":"Insufficiently Protected Credentials"},{"id":"CWE-256","name":"Plaintext Storage of a Password"}],"description":"Grundfos CIM 500 v06.16.00 stores plaintext credentials, which may allow sensitive information to be read or allow modification to system settings by someone with access to the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in CIM 500","id":"CVE-2020-10609","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in OSIsoft PI System multiple products and versions","id":"CVE-2020-10610"},"packages":[],"prev":{"headline":"Security feature bypass in OSIsoft PI System multiple products and versions","id":"CVE-2020-10608"},"products":["CIM 500"],"published":"2020-07-27","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Grundfos"]},"summary":"An attacker with device access can read plaintext credentials and modify system settings on Grundfos CIM 500 devices.","url":"https://insights.sbomify.com/CVE-2020-10609/"}