{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-10611 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-10611 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-10611 is a critical memory corruption vulnerability in Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122, published on 15 Apr 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-10611 and fix it if it is affected.\n\nWhat it is: CVE-2020-10611 is a critical memory corruption vulnerability in Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122, published on 15 Apr 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-10611 in the wild and no public exploit code.\n\nAffected product: Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-10611/ (Markdown: https://insights.sbomify.com/CVE-2020-10611/index.md)","id":"CVE-2020-10611","markdown":"https://insights.sbomify.com/CVE-2020-10611/index.md","name":"CVE-2020-10611","record":{"aliases":["GHSA-grj9-c593-w7c6"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":true,"product_category":"SCADA Data Gateway","requires_auth":"none","summary":"Remote attackers can execute arbitrary code via type confusion in DNP3 Data Sets, requiring no authentication.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"scada_data_gateway","vendor":"trianglemicroworks"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-843","name":"Access of Resource Using Incompatible Type"}],"description":"Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","id":"CVE-2020-10611","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Missing authorization in Opto 22 SoftPAC Project","id":"CVE-2020-10612"},"packages":[],"prev":{"headline":"Path traversal in OSIsoft PI System multiple products and versions","id":"CVE-2020-10610"},"products":["Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122"],"published":"2020-04-15","related":[{"cvss_score":9.8,"headline":"Triangle MicroWorks SCADA Data Gateway Missing Authentication Vulnerability","id":"CVE-2023-39457","kev_date_added":null,"published":"2024-05-03"},{"cvss_score":8.2,"headline":"Other in SCADA Data Gateway","id":"CVE-2023-2186","kev_date_added":null,"published":"2023-06-07"},{"cvss_score":7.8,"headline":"Triangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability","id":"CVE-2023-39459","kev_date_added":null,"published":"2024-05-03"},{"cvss_score":7.5,"headline":"Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability","id":"CVE-2023-39465","kev_date_added":null,"published":"2024-05-03"},{"cvss_score":7.5,"headline":"Information disclosure in Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","id":"CVE-2020-10613","kev_date_added":null,"published":"2020-04-15"},{"cvss_score":7.5,"headline":"Memory corruption in Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122","id":"CVE-2020-10615","kev_date_added":null,"published":"2020-04-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Remote attackers can execute arbitrary code via type confusion in DNP3 Data Sets, requiring no authentication.","url":"https://insights.sbomify.com/CVE-2020-10611/"}