{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2020-11952 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-11952 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-11952 is a medium-severity authentication bypass vulnerability in n/a, published on 14 Jul 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-11952 and fix it if it is affected.\n\nWhat it is: CVE-2020-11952 is a medium-severity authentication bypass vulnerability in n/a, published on 14 Jul 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-11952 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-11952/ (Markdown: https://insights.sbomify.com/CVE-2020-11952/index.md)","id":"CVE-2020-11952","markdown":"https://insights.sbomify.com/CVE-2020-11952/index.md","name":"CVE-2020-11952","record":{"aliases":["GHSA-jq3h-gh6x-8549"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Rittal PDU/CMC","requires_auth":"none","summary":"Attackers can bypass the CLI menu on Rittal PDU and CMC devices, potentially gaining unauthorized access to device controls.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"cmc_iii_pu_7030.000_firmware","vendor":"rittal"},{"product":"cmciii-pu-9333e0fb_firmware","vendor":"rittal"},{"product":"iot_interface_3124.300","vendor":"rittal"},{"product":"lcp-cw_firmware","vendor":"rittal"},{"product":"pdu-3c002dec_firmware","vendor":"rittal"}],"cvss":{"score":6.2,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[],"description":"An issue was discovered on Rittal PDU-3C002DEC through 5.17.10 and CMCIII-PU-9333E0FB through 3.17.10 devices. Attackers can bypass the CLI menu.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in n/a","id":"CVE-2020-11952","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in n/a","id":"CVE-2020-11953"},"packages":[],"prev":{"headline":"Hardcoded credentials in n/a","id":"CVE-2020-11951"},"products":["n/a"],"published":"2020-07-14","related":[{"cvss_score":9.8,"headline":"Hardcoded credentials in n/a","id":"CVE-2020-11951","kev_date_added":null,"published":"2020-07-14"},{"cvss_score":9.8,"headline":"Privilege escalation in n/a","id":"CVE-2020-11956","kev_date_added":null,"published":"2020-07-14"},{"cvss_score":8.8,"headline":"Command injection in n/a","id":"CVE-2020-11953","kev_date_added":null,"published":"2020-07-14"},{"cvss_score":8.8,"headline":"Misconfiguration in n/a","id":"CVE-2020-11955","kev_date_added":null,"published":"2020-07-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Attackers can bypass the CLI menu on Rittal PDU and CMC devices, potentially gaining unauthorized access to device controls.","url":"https://insights.sbomify.com/CVE-2020-11952/"}