{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-12000 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-12000 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-12000 is a high-severity unsafe deserialization vulnerability in Ignition 8 Gateway, published on 9 Jun 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-12000 and fix it if it is affected.\n\nWhat it is: CVE-2020-12000 is a high-severity unsafe deserialization vulnerability in Ignition 8 Gateway, published on 9 Jun 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-12000 in the wild and no public exploit code.\n\nAffected product: Ignition 8 Gateway. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-12000/ (Markdown: https://insights.sbomify.com/CVE-2020-12000/index.md)","id":"CVE-2020-12000","markdown":"https://insights.sbomify.com/CVE-2020-12000/index.md","name":"CVE-2020-12000","record":{"aliases":["GHSA-gh6q-wrfg-c8wf"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Ignition SCADA Gateway","requires_auth":"none","summary":"An attacker can exploit improper validation of serialized data in Ignition Gateway to obtain sensitive information.","user_interaction":"not_required","vuln_class":"deserialization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"ignition_gateway","vendor":"inductiveautomation"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-502","name":"Deserialization of Untrusted Data"}],"description":"The affected product is vulnerable to the handling of serialized data. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Deserialization in Ignition 8 Gateway","id":"CVE-2020-12000","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"deserialization","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software","id":"CVE-2020-12001"},"packages":[],"prev":{"headline":"Code injection in FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software","id":"CVE-2020-11999"},"products":["Ignition 8 Gateway"],"published":"2020-06-09","related":[{"cvss_score":7.5,"headline":"The affected product is vulnerable to an information leak, which may allow an attacker to obtain sensitive information on the Ignition 8 (al","id":"CVE-2020-14520","kev_date_added":null,"published":"2020-07-31"},{"cvss_score":7.5,"headline":"Deserialization in Ignition 8 Gateway","id":"CVE-2020-10644","kev_date_added":null,"published":"2020-06-09"},{"cvss_score":7.5,"headline":"Missing authorization in Ignition 8 Gateway","id":"CVE-2020-12004","kev_date_added":null,"published":"2020-06-09"},{"cvss_score":7.5,"headline":"Missing authorization in Ignition 8 Gateway","id":"CVE-2020-10641","kev_date_added":null,"published":"2020-04-28"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"An attacker can exploit improper validation of serialized data in Ignition Gateway to obtain sensitive information.","url":"https://insights.sbomify.com/CVE-2020-12000/"}