{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2020-12001 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-12001 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-12001 is a critical path traversal vulnerability in FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software, published on 15 Jun 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-12001 and fix it if it is affected.\n\nWhat it is: CVE-2020-12001 is a critical path traversal vulnerability in FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software, published on 15 Jun 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-12001 in the wild and no public exploit code.\n\nAffected product: FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-12001/ (Markdown: https://insights.sbomify.com/CVE-2020-12001/index.md)","id":"CVE-2020-12001","markdown":"https://insights.sbomify.com/CVE-2020-12001/index.md","name":"CVE-2020-12001","record":{"aliases":["GHSA-rq3q-m2cf-pq6x"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","data_modify","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Rockwell Automation software","requires_auth":"none","summary":"Attackers can use specially crafted files to traverse the file system, exposing sensitive data or executing arbitrary code in Rockwell Automation industrial software.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"factorytalk_linx","vendor":"rockwellautomation"},{"product":"rslinx_classic","vendor":"rockwellautomation"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software","id":"CVE-2020-12001","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Memory corruption in Advantech WebAccess Node","id":"CVE-2020-12002"},"packages":[],"prev":{"headline":"Deserialization in Ignition 8 Gateway","id":"CVE-2020-12000"},"products":["FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software"],"published":"2020-06-15","related":[{"cvss_score":9.8,"headline":"Memory corruption in FactoryTalk Linx","id":"CVE-2020-27251","kev_date_added":null,"published":"2020-11-26"},{"cvss_score":8.5,"headline":"Rockwell Automation FactoryTalk® Linx Privilege Escalation Vulnerabilities","id":"CVE-2025-9067","kev_date_added":null,"published":"2025-10-14"},{"cvss_score":8.5,"headline":"Rockwell Automation FactoryTalk® Linx Privilege Escalation Vulnerabilities","id":"CVE-2025-9068","kev_date_added":null,"published":"2025-10-14"},{"cvss_score":8.4,"headline":"Rockwell Automation FactoryTalk® Linx Network Browser Security Bypass Vulnerability","id":"CVE-2025-7972","kev_date_added":null,"published":"2025-08-14"},{"cvss_score":8.2,"headline":"Rockwell Automation FactoryTalk Linx Vulnerable to Denial-of-Service and Information Disclosure","id":"CVE-2023-29464","kev_date_added":null,"published":"2023-10-13"},{"cvss_score":8.1,"headline":"Code injection in FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software","id":"CVE-2020-11999","kev_date_added":null,"published":"2020-06-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Attackers can use specially crafted files to traverse the file system, exposing sensitive data or executing arbitrary code in Rockwell Automation industrial software.","url":"https://insights.sbomify.com/CVE-2020-12001/"}