{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2020-12008 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-12008 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-12008 is a high-severity vulnerability in Baxter ExactaMix EM 2400 \u0026 EM 1200, published on 29 Jun 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-12008 and fix it if it is affected.\n\nWhat it is: CVE-2020-12008 is a high-severity vulnerability in Baxter ExactaMix EM 2400 \u0026 EM 1200, published on 29 Jun 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-12008 in the wild and no public exploit code.\n\nAffected product: Baxter ExactaMix EM 2400 \u0026 EM 1200. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-12008/ (Markdown: https://insights.sbomify.com/CVE-2020-12008/index.md)","id":"CVE-2020-12008","markdown":"https://insights.sbomify.com/CVE-2020-12008/index.md","name":"CVE-2020-12008","record":{"aliases":["GHSA-pq8r-49xc-839h"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Pharmacy compounding robot","requires_auth":"none","summary":"An attacker with network access can view sensitive patient data transmitted in cleartext by Baxter ExactaMix systems.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"em1200_firmware","vendor":"baxter"},{"product":"em2400_firmware","vendor":"baxter"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"Baxter ExactaMix EM 2400 Versions 1.10, 1.11 and ExactaMix EM1200 Versions 1.1, 1.2 systems use cleartext messages to communicate order information with an order entry system. This could allow an attacker with network access to view sensitive data including PHI.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12008","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Deserialization in GenBroker32","id":"CVE-2020-12009"},"packages":[],"prev":{"headline":"Deserialization in GenBroker32","id":"CVE-2020-12007"},"products":["Baxter ExactaMix EM 2400 \u0026 EM 1200"],"published":"2020-06-29","related":[{"cvss_score":9.8,"headline":"Hardcoded credentials in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12016","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.1,"headline":"Information disclosure in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12032","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":6.1,"headline":"Hardcoded credentials in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12012","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":6.1,"headline":"Privilege escalation in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12020","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":6.1,"headline":"Missing authorization in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12024","kev_date_added":null,"published":"2020-06-29"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"An attacker with network access can view sensitive patient data transmitted in cleartext by Baxter ExactaMix systems.","url":"https://insights.sbomify.com/CVE-2020-12008/"}