{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2020-12016 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-12016 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-12016 is a critical vulnerability in Baxter ExactaMix EM 2400 \u0026 EM 1200, published on 29 Jun 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-12016 and fix it if it is affected.\n\nWhat it is: CVE-2020-12016 is a critical vulnerability in Baxter ExactaMix EM 2400 \u0026 EM 1200, published on 29 Jun 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-12016 in the wild and no public exploit code.\n\nAffected product: Baxter ExactaMix EM 2400 \u0026 EM 1200. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-12016/ (Markdown: https://insights.sbomify.com/CVE-2020-12016/index.md)","id":"CVE-2020-12016","markdown":"https://insights.sbomify.com/CVE-2020-12016/index.md","name":"CVE-2020-12016","record":{"aliases":["GHSA-x46p-33c9-vprq"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Pharmacy compounding robot","requires_auth":"none","summary":"Hard-coded administrative credentials in Baxter ExactaMix systems allow attackers with network access to view sensitive data and modify system configuration.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"em1200_firmware","vendor":"baxter"},{"product":"em2400_firmware","vendor":"baxter"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"},{"id":"CWE-259","name":"Use of Hard-coded Password"}],"description":"Baxter ExactaMix EM 2400 \u0026 EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12016","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in GE Grid Solutions Reason RT Clocks","id":"CVE-2020-12017"},"packages":[],"prev":{"headline":"Deserialization in GenBroker32","id":"CVE-2020-12015"},"products":["Baxter ExactaMix EM 2400 \u0026 EM 1200"],"published":"2020-06-29","related":[{"cvss_score":9.1,"headline":"Information disclosure in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12032","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":7.5,"headline":"Information disclosure in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12008","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":6.1,"headline":"Hardcoded credentials in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12012","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":6.1,"headline":"Privilege escalation in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12020","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":6.1,"headline":"Missing authorization in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12024","kev_date_added":null,"published":"2020-06-29"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Hard-coded administrative credentials in Baxter ExactaMix systems allow attackers with network access to view sensitive data and modify system configuration.","url":"https://insights.sbomify.com/CVE-2020-12016/"}