{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-12023 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-12023 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-12023 is a low-severity vulnerability in Philips IntelliBridge Enterprise (IBE), published on 11 Jun 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-12023 and fix it if it is affected.\n\nWhat it is: CVE-2020-12023 is a low-severity vulnerability in Philips IntelliBridge Enterprise (IBE), published on 11 Jun 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-12023 in the wild and no public exploit code.\n\nAffected product: Philips IntelliBridge Enterprise (IBE). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-12023/ (Markdown: https://insights.sbomify.com/CVE-2020-12023/index.md)","id":"CVE-2020-12023","markdown":"https://insights.sbomify.com/CVE-2020-12023/index.md","name":"CVE-2020-12023","record":{"aliases":["GHSA-865m-f7p5-xc5c"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Philips IntelliBridge Enterprise","requires_auth":"high_privilege","summary":"An attacker with administrative privileges can read unencrypted user credentials from transaction logs in Philips IntelliBridge Enterprise.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"intellibridge_enterprise","vendor":"philips"}],"cvss":{"score":2,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-532","name":"Insertion of Sensitive Information into Log File"}],"description":"Philips IntelliBridge Enterprise (IBE), Versions B.12 and prior, IntelliBridge Enterprise system integration with SureSigns (VS4), EarlyVue (VS30) and IntelliVue Guardian (IGS). Unencrypted user credentials received in the IntelliBridge Enterprise (IBE) are logged within the transaction logs, which are secured behind the login based administrative web portal. The unencrypted user credentials sent from the affected products listed above, for the purpose of handshake or authentication with the Enterprise Systems, are logged as the payload in IntelliBridge Enterprise (IBE) within the transaction logs. An attacker with administrative privileges could exploit this vulnerability to read plain text credentials from log files.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Philips IntelliBridge Enterprise IBE Insertion of Sensitive Information into Log File","id":"CVE-2020-12023","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Missing authorization in Baxter ExactaMix EM 2400 \u0026 EM 1200","id":"CVE-2020-12024"},"packages":[],"prev":{"headline":"Code injection in Advantech WebAccess Node","id":"CVE-2020-12022"},"products":["IntelliBridge Enterprise (IBE)"],"published":"2020-06-11","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-06-04","vendors":["Philips"]},"summary":"An attacker with administrative privileges can read unencrypted user credentials from transaction logs in Philips IntelliBridge Enterprise.","url":"https://insights.sbomify.com/CVE-2020-12023/"}