{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2020-12034 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-12034 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-12034 is a high-severity SQL injection vulnerability in EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software, published on 20 May 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-12034 and fix it if it is affected.\n\nWhat it is: CVE-2020-12034 is a high-severity SQL injection vulnerability in EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software, published on 20 May 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-12034 in the wild and no public exploit code.\n\nAffected product: EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-12034/ (Markdown: https://insights.sbomify.com/CVE-2020-12034/index.md)","id":"CVE-2020-12034","markdown":"https://insights.sbomify.com/CVE-2020-12034/index.md","name":"CVE-2020-12034","record":{"aliases":["GHSA-q6xv-fmfc-gjvg"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Industrial Automation Software","requires_auth":"none","summary":"Attackers can inject SQL queries via crafted EDS files to manipulate the database, causing denial-of-service in industrial automation software.","user_interaction":"not_required","vuln_class":"sql_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"eds_subsystem","vendor":"rockwellautomation"},{"product":"rslinx","vendor":"rockwellautomation"},{"product":"rslinx_enterprise","vendor":"rockwellautomation"},{"product":"rsnetworx","vendor":"rockwellautomation"},{"product":"studio_5000_logix_designer","vendor":"rockwellautomation"}],"cvss":{"score":8.2,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:H","version":"3.1"},"cwes":[{"id":"CWE-89","name":"Improper Neutralization of Special Elements used in an SQL Command"}],"description":"Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"SQL injection in EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software","id":"CVE-2020-12034","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"sql_injection","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Hardcoded credentials in Baxter PrismaFlex and PrisMax","id":"CVE-2020-12035"},"packages":[],"prev":{"headline":"Missing authorization in Rockwell Automation FactoryTalk Services Platform","id":"CVE-2020-12033"},"products":["EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software"],"published":"2020-05-20","related":[{"cvss_score":5.5,"headline":"Memory corruption in EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software","id":"CVE-2020-12038","kev_date_added":null,"published":"2020-05-19"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Attackers can inject SQL queries via crafted EDS files to manipulate the database, causing denial-of-service in industrial automation software.","url":"https://insights.sbomify.com/CVE-2020-12034/"}