{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-12039 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-12039 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-12039 is a low-severity vulnerability in Baxter Sigma Spectrum Infusion Pumps, published on 29 Jun 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-12039 and fix it if it is affected.\n\nWhat it is: CVE-2020-12039 is a low-severity vulnerability in Baxter Sigma Spectrum Infusion Pumps, published on 29 Jun 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-12039 in the wild and no public exploit code.\n\nAffected product: Baxter Sigma Spectrum Infusion Pumps. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-12039/ (Markdown: https://insights.sbomify.com/CVE-2020-12039/index.md)","id":"CVE-2020-12039","markdown":"https://insights.sbomify.com/CVE-2020-12039/index.md","name":"CVE-2020-12039","record":{"aliases":["GHSA-r4xc-rmm6-cf36"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["privilege_escalation","data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Infusion pump","requires_auth":"none","summary":"Hardcoded passwords allow physical attackers to access biomedical menus, view calibration values, and modify network configurations on Baxter infusion pumps.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"sigma_spectrum_infusion_system_firmware","vendor":"baxter"}],"cvss":{"score":2.4,"severity":"low","source":"nvd","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"},{"id":"CWE-259","name":"Use of Hard-coded Password"}],"description":"Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX \u0026 Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12039","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12040"},"packages":[],"prev":{"headline":"Memory corruption in EDS Subsystem, FactoryTalk Linx software (Previously called RSLinx Enterprise), RSLinx Classic, RSNetWorx software, Studio 5000 Logix Designer software","id":"CVE-2020-12038"},"products":["Baxter Sigma Spectrum Infusion Pumps"],"published":"2020-06-29","related":[{"cvss_score":9.8,"headline":"Information disclosure in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12040","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.8,"headline":"Security feature bypass in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12043","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.8,"headline":"Hardcoded credentials in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12045","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.8,"headline":"Hardcoded credentials in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12047","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.8,"headline":"Auth bypass in SIGMA Spectrum Infusion System","id":"CVE-2014-5432","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":9.8,"headline":"Information disclosure in SIGMA Spectrum Infusion System","id":"CVE-2014-5433","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":9.8,"headline":"Hardcoded credentials in SIGMA Spectrum Infusion System","id":"CVE-2014-5434","kev_date_added":null,"published":"2019-03-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"Hardcoded passwords allow physical attackers to access biomedical menus, view calibration values, and modify network configurations on Baxter infusion pumps.","url":"https://insights.sbomify.com/CVE-2020-12039/"}