{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-12040 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-12040 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-12040 is a critical vulnerability in Baxter Sigma Spectrum Infusion Pumps, published on 29 Jun 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-12040 and fix it if it is affected.\n\nWhat it is: CVE-2020-12040 is a critical vulnerability in Baxter Sigma Spectrum Infusion Pumps, published on 29 Jun 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-12040 in the wild and no public exploit code.\n\nAffected product: Baxter Sigma Spectrum Infusion Pumps. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-12040/ (Markdown: https://insights.sbomify.com/CVE-2020-12040/index.md)","id":"CVE-2020-12040","markdown":"https://insights.sbomify.com/CVE-2020-12040/index.md","name":"CVE-2020-12040","record":{"aliases":["GHSA-mr8w-rm42-6ph4"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical infusion pump","requires_auth":"none","summary":"An attacker with network access can intercept unencrypted medical device data or perform man-in-the-middle attacks due to lack of authentication and encryption.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"sigma_spectrum_infusion_system_firmware","vendor":"baxter"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-319","name":"Cleartext Transmission of Sensitive Information"}],"description":"Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12040","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12041"},"packages":[],"prev":{"headline":"Hardcoded credentials in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12039"},"products":["Baxter Sigma Spectrum Infusion Pumps"],"published":"2020-06-29","related":[{"cvss_score":9.8,"headline":"Security feature bypass in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12043","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.8,"headline":"Hardcoded credentials in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12045","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.8,"headline":"Hardcoded credentials in Baxter Sigma Spectrum Infusion Pumps","id":"CVE-2020-12047","kev_date_added":null,"published":"2020-06-29"},{"cvss_score":9.8,"headline":"Auth bypass in SIGMA Spectrum Infusion System","id":"CVE-2014-5432","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":9.8,"headline":"Information disclosure in SIGMA Spectrum Infusion System","id":"CVE-2014-5433","kev_date_added":null,"published":"2019-03-26"},{"cvss_score":9.8,"headline":"Hardcoded credentials in SIGMA Spectrum Infusion System","id":"CVE-2014-5434","kev_date_added":null,"published":"2019-03-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"An attacker with network access can intercept unencrypted medical device data or perform man-in-the-middle attacks due to lack of authentication and encryption.","url":"https://insights.sbomify.com/CVE-2020-12040/"}