CVE-2020-12733 Hardcoded credentials in n/a
Attackers can gain administrative access to Shenzhen PENGLIXIN WiFi Digital Microscopes via Telnet using hardcoded credentials.
- Exploited in the wild
- Not known
- Login needed
- Not needed
- Attackable
- Over the internet
- Victim action needed
- Not needed
- Fix
- None listed
What is CVE-2020-12733?
CVE-2020-12733 is a high-severity vulnerability in n/a, published on 15 Jul 2021. An attacker can exploit it over the internet without logging in, with no action from the victim.
Official description
Certain Shenzhen PENGLIXIN components on DEPSTECH WiFi Digital Microscope 3, as used by Shekar Endoscope, allow a TELNET connection with the molinkadmin password for the molink account.
Weakness: CWE-863
Which versions are affected by CVE-2020-12733?
It affects 1 product.
Products include Depstech Wifi Digital Microscope 3 Firmware.
How do I fix CVE-2020-12733?
No fix has been published for CVE-2020-12733 yet. Limit exposure of the affected software until one is available.
Is CVE-2020-12733 being exploited?
There is no known exploitation of CVE-2020-12733 in the wild and no public exploit code.