{"answers":{"affected":"It affects 8 products.","exploited":"There is no known exploitation of CVE-2020-14477 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-14477 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-14477 is a low-severity authentication bypass vulnerability in Philips Ultrasound CX, published on 26 Jun 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-14477 and fix it if it is affected.\n\nWhat it is: CVE-2020-14477 is a low-severity authentication bypass vulnerability in Philips Ultrasound CX, published on 26 Jun 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-14477 in the wild and no public exploit code.\n\nAffected product: Philips Ultrasound CX. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-14477/ (Markdown: https://insights.sbomify.com/CVE-2020-14477/index.md)","id":"CVE-2020-14477","markdown":"https://insights.sbomify.com/CVE-2020-14477/index.md","name":"CVE-2020-14477","record":{"aliases":["GHSA-p4jj-wjcf-vhhr"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["data_read","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Philips Ultrasound Systems","requires_auth":"low_privilege","summary":"Attackers can bypass authentication via alternate channels to view or modify information on Philips Ultrasound systems.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"affiniti_50_firmware","vendor":"philips"},{"product":"affiniti_70_firmware","vendor":"philips"},{"product":"clearvue_350_firmware","vendor":"philips"},{"product":"clearvue_850_firmware","vendor":"philips"},{"product":"cx50_firmware","vendor":"philips"},{"product":"epiq_7_firmware","vendor":"philips"},{"product":"sparq_firmware","vendor":"philips"},{"product":"xperius_firmware","vendor":"philips"}],"cvss":{"score":3.6,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-287","name":"Improper Authentication"},{"id":"CWE-288","name":"Authentication Bypass Using an Alternate Path or Channel"}],"description":"In Philips Ultrasound ClearVue Versions 3.2 and prior, Ultrasound CX Versions 5.0.2 and prior, Ultrasound EPIQ/Affiniti Versions VM5.0 and prior, Ultrasound Sparq Version 3.0.2 and prior and Ultrasound Xperius all versions, an attacker may use an alternate path or channel that does not require authentication of the alternate service login to view or modify information.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Philips Ultrasound Systems Authentication Bypass Using an Alternate Path or Channel","id":"CVE-2020-14477","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2020"},"n_packages":0,"n_references":1,"next":{"headline":"IMPROPER RESTRICTION OF XML EXTERNAL ENTITY REFERENCE CWE-611","id":"CVE-2020-14478"},"packages":[],"prev":{"headline":"DO NOT USE THIS CANDIDATE NUMBER.","id":"CVE-2020-14476"},"products":["Ultrasound CX","Ultrasound ClearVue","Ultrasound EPIQ/Affiniti","Ultrasound Sparq","Ultrasound Xperius"],"published":"2020-06-26","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-06-04","vendors":["Philips"]},"summary":"Attackers can bypass authentication via alternate channels to view or modify information on Philips Ultrasound systems.","url":"https://insights.sbomify.com/CVE-2020-14477/"}