{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-14525 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-14525 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-14525 is a low-severity cross-site scripting vulnerability in Philips Clinical Collaboration Platform, published on 18 Sep 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-14525 and fix it if it is affected.\n\nWhat it is: CVE-2020-14525 is a low-severity cross-site scripting vulnerability in Philips Clinical Collaboration Platform, published on 18 Sep 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-14525 in the wild and no public exploit code.\n\nAffected product: Philips Clinical Collaboration Platform. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-14525/ (Markdown: https://insights.sbomify.com/CVE-2020-14525/index.md)","id":"CVE-2020-14525","markdown":"https://insights.sbomify.com/CVE-2020-14525/index.md","name":"CVE-2020-14525","record":{"aliases":["GHSA-779w-7mcf-pvxf"],"analysis":{"component_type":"web_application","fix_type":"patch","impacts":["code_execution","account_takeover"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Clinical Collaboration Platform","requires_auth":"low_privilege","summary":"Attackers can inject malicious scripts into web pages served to other users, potentially leading to code execution or account takeover.","user_interaction":"not_required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"clinical_collaboration_platform","vendor":"philips"}],"cvss":{"score":3.5,"severity":"low","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-83","name":"Improper Neutralization of Script in Attributes in a Web Page"}],"description":"Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input \nbefore it is placed in output used as a webpage that is served to other \nusers.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Philips Clinical Collaboration Platform Improper Neutralization of Script in Attributes in a Web Page","id":"CVE-2020-14525","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Information disclosure in Primavera Portfolio Management","id":"CVE-2020-14527"},"packages":[],"prev":{"headline":"Softing Industrial Automation OPC","id":"CVE-2020-14524"},"products":["Clinical Collaboration Platform"],"published":"2020-09-18","related":[{"cvss_score":6.8,"headline":"Philips Clinical Collaboration Platform Configuration","id":"CVE-2020-16247","kev_date_added":null,"published":"2020-09-18"},{"cvss_score":6.5,"headline":"Command injection in n/a","id":"CVE-2025-27953","kev_date_added":null,"published":"2025-06-02"},{"cvss_score":6.5,"headline":"Command injection in n/a","id":"CVE-2025-27954","kev_date_added":null,"published":"2025-06-02"},{"cvss_score":6.5,"headline":"Security feature bypass in n/a","id":"CVE-2025-27955","kev_date_added":null,"published":"2025-06-02"},{"cvss_score":6.5,"headline":"Philips Clinical Collaboration Platform Algorithm Downgrade","id":"CVE-2020-16200","kev_date_added":null,"published":"2020-09-18"},{"cvss_score":5,"headline":"Philips Clinical Collaboration Platform Protection Mechanism Failure","id":"CVE-2020-16198","kev_date_added":null,"published":"2020-09-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-06-04","vendors":["Philips"]},"summary":"Attackers can inject malicious scripts into web pages served to other users, potentially leading to code execution or account takeover.","url":"https://insights.sbomify.com/CVE-2020-14525/"}