{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2020-16200 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-16200 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-16200 is a medium-severity denial of service vulnerability in Philips Clinical Collaboration Platform, published on 18 Sep 2020. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-16200 and fix it if it is affected.\n\nWhat it is: CVE-2020-16200 is a medium-severity denial of service vulnerability in Philips Clinical Collaboration Platform, published on 18 Sep 2020. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-16200 in the wild and no public exploit code.\n\nAffected product: Philips Clinical Collaboration Platform. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-16200/ (Markdown: https://insights.sbomify.com/CVE-2020-16200/index.md)","id":"CVE-2020-16200","markdown":"https://insights.sbomify.com/CVE-2020-16200/index.md","name":"CVE-2020-16200","record":{"aliases":["GHSA-vq75-425f-vq6r"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Clinical Collaboration Platform","requires_auth":"none","summary":"An attacker can exhaust system resources in the Philips Clinical Collaboration Platform, causing a denial of service.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"clinical_collaboration_platform","vendor":"philips"}],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-757","name":"Selection of Less-Secure Algorithm During Negotiation"}],"description":"Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, \n\ndoes not properly control the allocation and maintenance of a limited \nresource, thereby enabling an attacker to influence the amount of \nresources consumed, eventually leading to the exhaustion of available \nresources.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Philips Clinical Collaboration Platform Algorithm Downgrade","id":"CVE-2020-16200","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2020"},"n_packages":0,"n_references":2,"next":{"headline":"Information disclosure in Delta Industrial Automation CNCSoft ScreenEditor","id":"CVE-2020-16201"},"packages":[],"prev":{"headline":"Memory corruption in Delta Industrial Automation CNCSoft ScreenEditor","id":"CVE-2020-16199"},"products":["Clinical Collaboration Platform"],"published":"2020-09-18","related":[{"cvss_score":6.8,"headline":"Philips Clinical Collaboration Platform Configuration","id":"CVE-2020-16247","kev_date_added":null,"published":"2020-09-18"},{"cvss_score":6.5,"headline":"Command injection in n/a","id":"CVE-2025-27953","kev_date_added":null,"published":"2025-06-02"},{"cvss_score":6.5,"headline":"Command injection in n/a","id":"CVE-2025-27954","kev_date_added":null,"published":"2025-06-02"},{"cvss_score":6.5,"headline":"Security feature bypass in n/a","id":"CVE-2025-27955","kev_date_added":null,"published":"2025-06-02"},{"cvss_score":5,"headline":"Philips Clinical Collaboration Platform Protection Mechanism Failure","id":"CVE-2020-16198","kev_date_added":null,"published":"2020-09-18"},{"cvss_score":3.5,"headline":"Philips Clinical Collaboration Platform Improper Neutralization of Script in Attributes in a Web Page","id":"CVE-2020-14525","kev_date_added":null,"published":"2020-09-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-06-04","vendors":["Philips"]},"summary":"An attacker can exhaust system resources in the Philips Clinical Collaboration Platform, causing a denial of service.","url":"https://insights.sbomify.com/CVE-2020-16200/"}