{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2020-16204 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2020-16204 yet. Limit exposure of the affected software until one is available.","what":"CVE-2020-16204 is a critical command injection vulnerability in N-Tron 702-W / 702M12-W, published on 1 Sep 2020. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2020-16204 and fix it if it is affected.\n\nWhat it is: CVE-2020-16204 is a critical command injection vulnerability in N-Tron 702-W / 702M12-W, published on 1 Sep 2020. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2020-16204 in the wild and no public exploit code.\n\nAffected product: N-Tron 702-W / 702M12-W. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2020-16204/ (Markdown: https://insights.sbomify.com/CVE-2020-16204/index.md)","id":"CVE-2020-16204","markdown":"https://insights.sbomify.com/CVE-2020-16204/index.md","name":"CVE-2020-16204","record":{"aliases":["GHSA-j6rh-h9wc-gh7j"],"analysis":{"component_type":"network_device","fix_type":"no_fix_stated","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial Ethernet Switch","requires_auth":"none","summary":"An attacker can execute arbitrary commands as root on N-Tron industrial switches via an undocumented interface, posing a critical risk to OT environments.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"n-tron_702-w_firmware","vendor":"redlion"},{"product":"n-tron_702m12-w_firmware","vendor":"redlion"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-912","name":"Hidden Functionality"}],"description":"The affected product is vulnerable due to an undocumented interface found on the device, which may allow an attacker to execute commands as root on the device on the N-Tron 702-W / 702M12-W (all versions).","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in N-Tron 702-W / 702M12-W","id":"CVE-2020-16204","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2020"},"n_packages":0,"n_references":3,"next":{"headline":"Command injection in G-Cam and G-Code","id":"CVE-2020-16205"},"packages":[],"prev":{"headline":"Null dereference in Delta Industrial Automation CNCSoft ScreenEditor","id":"CVE-2020-16203"},"products":["N-Tron 702-W / 702M12-W"],"published":"2020-09-01","related":[{"cvss_score":9,"headline":"Cross-site scripting in N-Tron 702-W / 702M12-W","id":"CVE-2020-16206","kev_date_added":null,"published":"2020-09-01"},{"cvss_score":9,"headline":"Cross-site scripting in N-Tron 702-W / 702M12-W","id":"CVE-2020-16210","kev_date_added":null,"published":"2020-09-01"},{"cvss_score":8.8,"headline":"Cross-site request forgery in N-Tron 702-W / 702M12-W","id":"CVE-2020-16208","kev_date_added":null,"published":"2020-09-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-04","vendors":["n/a"]},"summary":"An attacker can execute arbitrary commands as root on N-Tron industrial switches via an undocumented interface, posing a critical risk to OT environments.","url":"https://insights.sbomify.com/CVE-2020-16204/"}